Single in and out HPA Series frequency converter 500W-90KVA
Product characteristics:
● Output voltage: single voltage 0-330 v, three-phase 0-520v
● Output frequency: 40-4999.9hz programmable dial setting
● Voltage, frequency, current, power meter using 4-bit digital led display, convenient, easy to read, high resolution
● Voltage (V), frequency(HZ), current(A), capacity factor(W),power measurement at the same time, display, do not need to switch
● No radiation interference, including small harmonic components, and after special treatment, no interference.
● Pure, steady sinusoidal output
● Large capacity, small volume, light weight, high efficiency, mute device, high reliability.
● Strong overload capacity, instantaneous current can withstand 3 times the rated current.
● There are over-current, over-high temperature, short-circuit, instantaneous power failure protection and warning devices.
● Suitable for use in resistive, capacitive, inductive and other nonlinear loads.
Use occasion
● Overseas sales product testing
● Simulate the power grid condition of the product export destination.
● Forecast test of all kinds of product certification.
● Product life test.
● Power adaptability test in professional laboratory.
● Transformer, motor and other winding products frequency doubling test.
Technical parameters
Single input single output | HPA-11005 | HPA-1101 | HPA-1102 | HPA-1103 | HPA-1105 | HPA-1108 | HPA-1110 | HPA-1115 | HPA-1120 | HPA-1130 | HPA-1145 | HPA-1160 | HPA-1175 | HPA-1190 |
Capacity | 500W | 1KVA | 2KVA | 3KVA | 5KVA | 8KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 90KVA |
Circuit mode | IGBT VPMW Pulse width modulation method |
AC input | 1 phase 2 line+G 220V/50HZ,60HZ |
Output | Phases | Single phase |
Low voltage | 0V-150V Customizable according to customer requirements |
High voltage | 0V-300V Customizable according to customer requirements |
Frequency | 40.0HZ-499.9HZ |
Low maximum current | 4.2 | 8.4 | 16.8 | 25 | 42 | 66.7 | 84 | 125 | 168 | 250 | 375 | 500 | 625 | 750 |
High maximum current | 2.1 | 4.2 | 8.4 | 12.5 | 21 | 33.3 | 42 | 62.5 | 84 | 125 | 188 | 250 | 313 | 375 |
Frequency stability rate | ≦0.1% |
Load stability rate | ≦0.5% resistive load | ≦1% resistive load |
Waveform distortion factor | ≦1% resistive load | ≦2% resistive load |
Response time | ≦2ms |
Indicative resolution | Digital frequency meter | 4-digit, resolution 0.1hz |
Digital voltmeter | 4 - digit , resolution 0.1v |
Digital ammeter | A number below 4A: 0.001a 4A or more than 0.01A. |
Digital power meter | 4-digit, resolution 1w |
Protector | Overload, short circuit, over temperature, protection and warning |
cooling equipment | Forced fan cooling |
Environment | Working temperature | 0℃-45℃ |
Relative humidity | 0-90% non-condensing |
Size (high * wide * deep mm) | 180*430*460 | 700*350*540 | 900*400*650 | 1100*500*780 | 1200*710*860 | 1600*800*1100 |
Weight(KG) | 17 | 21 | 25 | 42 | 45 | 100 | 105 | 110 | 120 | 200 | 265 | 320 | 360 | 420 |