Single in and three out HPA series frequency converter 3kva ~ 100kva
Product characteristics
● Output voltage: single voltage 0-330 v, three-phase 0-520v
● Output frequency: 40-4999.9hz programmable dial setting
● Voltage, frequency, current, power meter using 4-bit digital led display, convenient, easy to read, high resolution
● Voltage (V), frequency(HZ), current(A), capacity factor(W),power measurement at the same time, display, do not need to switch
● No radiation interference, including small harmonic components, and after special treatment, no interference.
● Pure, steady sinusoidal output
● Large capacity, small volume, light weight, high efficiency, mute device, high reliability.
● Strong overload capacity, instantaneous current can withstand 3 times the rated current.
● There are over-current, over-high temperature, short-circuit, instantaneous power failure protection and warning devices.
● Suitable for use in resistive, capacitive, inductive and other nonlinear loads.
Use occasion
● Overseas sales product testing
● Simulate the power grid condition of the product export destination.
● Forecast test of all kinds of product certification.
● Product life test.
● Power adaptability test in professional laboratory.
● Transformer, motor and other winding products frequency doubling test.
Technical parameters
| Single in and three out | HPA-1303 | HPA-1306 | HPA-1310 | HPA-1315 | HPA-1320 | HPA-1330 | HPA-1345 | HPA-1360 | HPA-1375 | HPA-1390 | HPA-13100 |
| Capacity | 3KVA | 5KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 90KVA | 100KVA |
| Circuit mode | IGBT VPMW pulse width modulation method |
| AC input | 1 phase 2 line + G 220V/50HZ, 60HZ |
| Output | Phases | Three phase |
| Low voltage | 0V-260V (customizable according to customer requirements) |
| high voltage | 0V-520V (customizable according to customer requirements) |
| Frequency | 40.0HZ-499.9HZ |
|
| Low maximum current | 8.4 | 16.8 | 27.5 | 42 | 55.5 | 84 | 125 | 168 | 208 | 250 | 275 |
| High maximum current | 4.2 | 8.4 | 13.75 | 21 | 27.7 | 42 | 62.5 | 84 | 104 | 125 | 137.5 |
| Frequency stability rate | ≦0.1% |
| Load stability rate | ≦0.5%(resistive load) | ≦1%(resistive load) |
| Waveform distortion factor |
| ≦2%(resistive load) |
| Response time | ≦2ms |
| Indicative resolution | Digital frequency meter | 4 digits, resolution 0.1HZ |
| Digital voltage meter | 4 digits, resolution 0.1V |
| Digital ampere meter | 4 digits, resolution 4A or less: 0.001A 4A or more: 0.01A |
| Digital power meter | 4 digits, resolution 1W |
| Protective device | Overload, short circuit, over temperature, protection and warning |
| Cooling equipment | Forced fan cooling |
| Environment | Working temperature | 0℃-45℃ |
| Relative humidity | 0-90% (non-condensing state) |
| Size (high * wide * deep mm) | 700*300*540 | 900*400*650 | 1100*500*780 | 1200*710*860 | 1200*710*860 |
| Weight(KG) | 110 | 135 | 195 | 210 | 240 | 360 | 390 | 420 | 500 | 550 | 600 |