Three in and out HPA series frequency converter 10kva ~ 300kva
Product characteristics
● Output voltage: single voltage 0-330 v, three-phase 0-520v
● Output frequency: 40-4999.9hz programmable dial setting
● Voltage, frequency, current, power meter using 4-bit digital led display, convenient, easy to read, high resolution
● Voltage (V), frequency(HZ), current(A), capacity factor(W),power measurement at the same time, display, do not need to switch
● No radiation interference, including small harmonic components, and after special treatment, no interference.
● Pure, steady sinusoidal output
● Large capacity, small volume, light weight, high efficiency, mute device, high reliability.
● Strong overload capacity, instantaneous current can withstand 3 times the rated current.
● There are over-current, over-high temperature, short-circuit, instantaneous power failure protection and warning devices.
● Suitable for use in resistive, capacitive, inductive and other nonlinear loads.
Use occasion
● Overseas sales product testing
● Simulate the power grid condition of the product export destination.
● Forecast test of all kinds of product certification.
● Product life test.
● Power adaptability test in professional laboratory.
● Transformer, motor and other winding products frequency doubling test.
Technical parameters
Three in three out | HPA-3310 | HPA-3315 | HPA-3320 | HPA-3330 | HPA-3345 | HPA-3360 | HPA-3375 | HPA-33100 | HPA-33120 | HPA-33150 | HPA-33180 | HPA-33200 | HPA-33250 | HPA-33300 |
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA | 150KVA | 180KVA | 200KVA | 250KVA | 300KVA |
Circuit mode | IGBT VPMW pulse width modulation method |
AC input | 3 Phase 4 Line +G 380V±10%,/50HZ,60HZ |
Output | Phases | Three phase |
Low voltage | 0V-260V (customizable according to customer requirements) |
high voltage | 0V-520V (customizable according to customer requirements) |
Frequency | 40.0HZ-499.9HZ |
Low maximum current | 27.5 | 42 | 55.5 | 84 | 125 | 168 | 208 | 275 | 336 | 416 | 500 | 555 | 694 | 840 |
High maximum current | 13.75 | 21 | 27.7 | 42 | 62.5 | 84 | 104 | 137.5 | 168 | 208 | 250 | 277 | 347 | 420 |
Frequency stability rate | ≦0.1% |
Load stability rate | ≦0.5%(resistive load) | ≦1%(resistive load) |
Waveform distortion factor |
| ≦2%(resistive load) |
Response time | ≦2ms |
Indicative resolution | Digital frequency meter | 4 digits, resolution 0.1HZ |
Digital voltage meter | 4 digits, resolution 0.1V |
Digital ampere meter | 4 digits, resolution 4A or less: 0.001A 4A or more: 0.01A |
Digital power meter | 4 digits, resolution 1W |
Protective device | Overload, short circuit, over temperature, protection and warning |
Cooling equipment | Forced fan cooling |
Environment | Working temperature | 0℃-45℃ |
Relative humidity | 0-90% (non-condensing state) |
Size (high * wide * deep mm) | 900*400*650 | 1100*500*780 | 1200*710*855 | 1600*800*100 | 1600* | 1900*1200*1650 |
Weight(KG) | 195 | 210 | 240 | 360 | 390 | 450 | 525 | 720 | 960 | 1080 | 1150 | 1200 | 1300 | 2000 |