General Characteristics | ||||||
Rated Voltage (kV) | 7.2 | 12 | 17.5 | 24 | 36 | |
Insulation level* | ||||||
50Hz-1min (kV rms) | Insulation | 20 | 28 | 38 | 50 | 70 |
Isolation | 23 | 32 | 45 | 60 | 80 |
1.2/50μs (kV peak) | Insulation | 60 | 75 | 95 | 125 | 170 | |
Isolation | 70 | 85 | 110 | 145 | 195 | ||
Short-time withstand current | |||||||
Switch(kA/1s) | 25 | 630A | |||||
20 | 630A | ||||||
16 | 630A | ||||||
12.5 | 630A | ||||||
Disconnector(kA/1s) | 25 | 630-1250A | 1250A | ||||
20 | 630-1250A | ||||||
16 | 630-1250A | ||||||
12.5 | 630-1250A | ||||||
Maximum breaking capacity | |||||||
Transformer off load (A) | 16 | ||||||
Cables off load (A) | 31.5 | 50 | |||||
Switch (A) | 630 | ||||||
Fuse-switch** (kA) | 25 | 20 | |||||
The making capacity is equal to 2.5 times the short-time withstand current. (*) Equipped referring to installation guide, and setting up at an altitude below 1000m. (**) Depending on fuse characteristics | |||||||
Endurance | |||||||
units | Mechanical endurance | Electrical endurance | |||||
Switch Fuse-switch | IEC62271-103 1000 operations Class M1 | IEC62271-103 100 breaks at In, p.f.=0.7 Class E3 | |||||
Disconnector | IEC62271-102 1000 operations | ||||||
Temperatures | |||||||
The products must be stored in a dry area free from dust and with limited temperature variations | For stocking: from -40℃ to +70℃ For working: from -5 ℃ to +40℃ Other temperatures, consult us | ||||||
Standards FLN36 units meet all the following recommendations: Switch: IEC62271-103: High voltage switches - Part 1: switches for rated voltages above 1 kV and less or equal to 52 kV. Disconnector: IEC 62271-102: High-voltage alternating current disconnectors and earthing switches. Switch /disconnector: IEC 62271-200: A.C. metal-enclosed switchgear and controlgear for rated voltage above 1 kV and up to including 52 kV. VPIS: IEC 62271-206: High-voltage prefabricated switchgear and controlgear assemblies-Voltage presence indicating systems |
Switch or disconnector and earthing switch
Gas tightness
The three rotating contacts are placed in an enclosure filled with gas to a relative pressure of 0.4 bar (400 hPa) for FLN36 12-24 kV and 1 bar (1000 hPa) for FLN36 36 kV.
It satisfies “sealed pressure system" requirements and seal tightness is always factory checked.
Operating safety
the switch may be in one of three positions: “closed", “open", or “earthed", representing a natural interlocking system that prevents incorrect operation.
Moving-contact rotation is driven by a fast-acting mechanism that is independent of the action of the operator.
the device combines the breaking and disconnection functions.
the earthing switch placed in the SF6 has a short-circuit making capacity, in compliance with standards.
any accidental over-pressures are eliminated by the opening of the safety membrane, in which case the gas is directed toward the back of the unit, away from the operator.