How to tell if a soft starter is faulty
Date: 2022/11/3Read: 69

How to tell if a soft starter is faulty

May 05, 2022

How to tell if a soft starter is faulty

Soft starter is a kind of motor control equipment that integrates soft start, soft stop, light load energy saving and multi-function protection. The motor can be started smoothly without impact during the whole starting process, and various parameters in the starting process can be adjusted according to the characteristics of the motor load, such as current limit value, starting time, etc.

In the daily use of the soft starter, it is also extremely important to learn to judge whether the soft starter is faulty. The following soft starter manufacturer SAFESAV will let you know how to judge whether the soft starter is faulty! We usually use voltage, resistance, replacement, etc. to judge the fault of the soft starter, as follows:

1. Troubleshoot the fault according to the fault code displayed


Find the corresponding manual, compare the displayed fault code with the fault code to find the fault location and cause, perform real-time measurement, and make specific solutions.


2. Use conventional methods to troubleshoot


Once a fault occurs, we cannot see the fault location, and only find the fault in sub-regions according to the principle and physical wiring diagram. First the main circuit, then the control circuit, the main circuit checks whether the incoming voltage of the power supply is normal, then whether the voltage of the power supply terminal is normal, whether the voltage of the contactor coil is normal, whether the contacts are normal when the contactor is closed, and whether the three-phase power insulation test is normal. . After checking these parts, if there is no fault, check in the control circuit. Generally, the control power supply, button contacts, soft starter output contacts, etc. are detected.



For example, for a high-power squirrel-cage motor, when the start button is pressed again after a normal shutdown, the device cannot start normally. Use an electric pen to measure the coil of the intermediate relay, and the output contact of the soft starter is also empty, indicating that the output contact If it is not closed, then the equipment must not start normally! Analyze the reason; because the motor starts and stops the intermediate relay must be turned on or off, then it is very likely that the arc burns the relay contacts inside the soft starter, causing the contacts to contact defective, resulting in an open circuit failure. The solution at this time is to replace an identical soft starter.



For example, the internal relay contacts of the soft starter are burned due to arcing. The first is that the external intermediate relay is an inductive load, and the second is that the internal relay contacts of the soft starter are burned by the arc after a long time of use, resulting in poor contact. of