In the above finishing, we have already understood why the inverter is used to control the motor, and also how the inverter controls the motor. The inverter controls the motor, which can be summed up as nothing more than two points: First, the inverter controls the starting voltage and frequency of the motor; it achieves smooth start and smooth stop; the second is to use the inverter to adjust the speed of the motor, and adjust the motor by changing the frequency.
For induction motors, the maximum speed limit for speed regulation is not the frequency converter. For normal frequency converters, the maximum operating frequency in V/F mode will not be lower than 400Hz. For example, Siemens frequency converters are 600Hz; vector control, the highest The operating frequency limit is 200Hz-300Hz; the maximum operating frequency of servo control will be higher. Therefore, the landlord wants to increase the speed regulation of the induction motor to 100Hz, and there is no suspense and doubt in the aspect of the inverter. There are absolutely no technical barriers.
The mechanical structure of the induction motor, such as the rotor, is a squirrel cage structure. Therefore, its mechanical strength is related to the maximum design speed of the motor. The higher the speed, the greater the mechanical centrifugal force. The speed shall prevail, and its mechanical strength will not be infinite.
The rotor bearing of the induction motor also has a maximum speed limit. Therefore, for the high-speed operation of the overvalued standard, it is necessary to know the maximum speed limit of the rotor bearing, as long as it meets the requirements, it can be used.
It is impossible for the manufacturer to debug and verify the dynamic balance debugging and tuning of the induction motor rotor beyond its own design parameters. The dynamic balance is generally checked to meet the maximum speed calibrated by the motor at the factory.
To sum up, the induction motor frequency control, if the application of overclocking. The first is to check with the manufacturer of the induction motor you are using to see if this is possible. Or simply put forward your own requirements and customize the motor. To ensure reliability at the highest speed.
In addition, if you do not solve these problems by yourself, you should first determine the dynamic balance test of the motor rotor, and then confirm the limit speed of the bearing; if it exceeds the high-speed bearing, you need to replace the high-speed bearing to meet the needs of the site. In addition, heat dissipation issues should also be considered.
Finally, according to experience, if you want to run an induction motor within 100Hz, the induction motor with small and medium power within 100kW should be relatively acceptable. If it exceeds 100kW and above, it is best to customize it.