When the soft starter ATS48 is running in the bypass mode, if the incoming line end cannot be powered, what is the harm to the soft starter if the motor end is energized?
Date: 2022/11/3Read: 34

When the soft starter ATS48 is running in the bypass mode, if the incoming line end cannot be powered, what is the harm to the soft starter if the motor end is energized?

Nov 04, 2021

When the soft starter ATS48 is running in the bypass mode, if the incoming line end cannot be powered, what is the harm to the soft starter if the motor end is energized?


The soft starter should be installed firmly to ensure that the shell is grounded. One-time wiring: R.S.T is the incoming terminal, U, V.W is broken, and the PE terminal should be reliably grounded to the main PE row. Secondary wiring: According to customer requirements, select the corresponding control method according to the manual. The simplest and common method is: short-circuit the start and stop signal terminals, and add a start relay NO point to connect to COM. When the NO point is closed, the soft start starts, and when the NO point is opened, the soft start stops running. There is also a bypass terminal for connecting the bypass contactor coil. There are also faulty wiring terminals. Be sure to figure out whether the fault point is open or closed. If it is closed, add a fault relay.

The soft starter only works when the motor starts and stops. After the motor completes the start-up process, it is put into the bypass, and the bypass contactor sucks and the motor supplies power through the bypass contactor. The soft starter controls the conduction angle of the internal thyristor to make the voltage rise linearly to the rated voltage within a certain period of time (adjustable), reducing the impact of the motor on the grid when starting and stopping. In addition, it may be at the upper or lower end of the soft starter. Isolation contactor will be added. When designing, it should be ensured that the isolation contactor starts before soft start and stops after soft start. The start time difference should be at least 0.1 seconds, and the stop time difference should be greater than the soft start time by 0.1 seconds. Electric delay relay) Otherwise, the soft start cannot be soft stopped and a fault is reported. At this time, the soft start and stop mode can also be selected as: free stop to solve the problem.