Welcome Customer !

Membership

Zhejiang Saikong Electrical Technology Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 变频器

Xwboo>Technical Article>How to reduce electromagnetic interference in the design of inverter control system

Zhejiang Saikong Electrical Technology Co., Ltd.Free·1YRS

  • E-mail

    amy@safeinvert.com

  • Phone

  • Address

    #22 Liujiang Avenue, Liushi Town, Yueqing City, Zhejiang Province, China

Contact Now
How to reduce electromagnetic interference in the design of inverter control system
Date: 2022/11/4Read: 36

How to reduce electromagnetic interference in the design of inverter control system

Sep 22, 2021

How to reduce electromagnetic interference in the design of inverter control system

Controlling VFD emissions is very challenging. VFD efficiency comes at the expense of EMI performance. Trying to control the EMI performance of a VFD driver usually reduces efficiency and increases heat generation. Placing the filter component on the output may affect operation. Placing too much capacitance or inductance will change the voltage-current relationship and affect the operation of the motor. This can make it ineffective or generate too much heat and prematurely damage or destroy the solid state drive or motor. In most cases, a combination of filtering and shielded cables is necessary. Other methods such as switching the drive frequency can transfer the generated harmonics to a position where they meet the desired limit.


The by-product of VFD is electromagnetic (EM) radiation. In many industrial applications, typical EM radiation levels cause few problems with other equipment; however, in US commercial applications such as HVAC, EMC (Electromagnetic Compatibility) levels are regulated by Part 15 of the FCC (Federal Communications Commission). According to IEC61800-3, the European Union has defined EMC limits for most environments (including industry). Manufacturers provide various solutions for different levels of EMC, from drivers with fully integrated filters to completely independent filters connected in series between the driver and its power supply.



I think you will get two different answers. This question involves EMI radiation and immunity to EMI. I'm not sure what you are most interested in. There are standards for both, depending on the application. European industrial radiation standards are stricter than North American standards. The residential standards in the United States are the most stringent and difficult to achieve. Immunity will also be different, but most basic VFD designs are quite flexible, as far as EMI immunity is concerned. From my point of view, the biggest problem with VFD installation is wiring EMI radiation. Care must be taken to ensure that the power cord is separated or insulated from the control cord. There are standards around the world to prevent interference problems, but even if it is too cautious, it is reasonable to be cautious. The cable will radiate, and the control line will be picked up if it is nearby. This question is certainly not a new one, and it is well documented.


Electromagnetic interference (EMI), also known as electrical noise, is an unwanted signal generated by electrical and electronic equipment. EMIVFD problems can range from corrupted data transmission to damaged motor drives. Modern VFDs that use IGBT switches for motor frequency control are very efficient due to their high switching speeds. Unfortunately, high-speed switching also leads to higher EMI. Typical noise suppression solutions include ensuring that all components are properly grounded; using shielded power cords to connect the inverter to the motor, and correctly connecting the shield to the drive and motor ground; using built-in or external EMI filters; using twist control Line leads provide balanced capacitive coupling; and operate power and control wiring separately.


Electromagnetic interference may be the easiest to mitigate by increasing the distance between systems. Filters and ferrite cores can be used to further assist this problem.


The correct or adequately sized power supply is the key, because if the upstream transformer is too large for the driver, the impedance will be too low and cause many problems. A well-designed grounding system helps reduce noise. The use of isolation transformers or input line reactors, as well as the EMI and RF filters shown in the figure, are essential to solve the interference related to VFD. Isolation transformer (10 to 1 reduction in transmission noise) or input line reactor can reduce power line interference and reduce power line harmonics caused by AC drives, thereby affecting other equipment running on the same power supply. The input EMI filter can reduce the electromagnetic interference or noise on the input side of the AC drive. They comply with CE standards and are recommended for devices that are susceptible to electromagnetic interference. When installed on the input and/or output side of a VFD, the RF filter can reduce radio frequency interference or noise.


The best way to solve EMI problems is to apply recommended installation practices. For example, this includes determining the EMC area, determining which type of cable to use (shielded VFD cable) and how to wire it (separate appropriately) and ground. Only after using the appropriate EMC installation guidelines, we recommend providing filters and other interference suppression measures to achieve more suppression.


Most of the VFD is in the driver's electromagnetic interference (EMI), which does not affect the use of local electrical equipment in an industrial environment in any significant way. In sensitive environments, users may find it wise to implement some form of EMI mitigation. EMI is divided into two parts; conducted and radiated noise. When the output waveform of the driver converts the motor leads into a large antenna, radiated noise is generated. This type of noise can affect equipment close to the motor leads. It is always recommended to minimize the motor lead length to limit radiated noise. In addition, reducing the carrier frequency of the driver helps to reduce the amount of radiated noise. In order to completely eliminate radiated noise, armored/shielded cables or grounded metal conduits can be used. When the transformer provides current for the high-frequency switches required by the driver to generate its output waveform, the driver generates conduction noise. These high-frequency currents can negatively affect the operation of equipment on the same power supply. Reducing the driver's carrier frequency can help, but input filtering is required to significantly reduce these currents. Low-cost solutions include the use of ferrite cores.


Electromagnetic interference (commonly called "noise") on the feedback device can be very detrimental in a motion system. In a motion system, the driver tries to control its set speed based on the feedback it receives. Noise changes the feedback signal your drive receives and may be seen as a movement that your device will try to correct. In most motion systems, there is almost no room for error. To minimize the effects of electromagnetic interference, you should ensure that you use a properly grounded shielded twisted pair cable as the feedback device. In addition, please remember that the most common cause of electromagnetic interference in the motion system is the high-voltage side of the drive itself, so try not to run the high-voltage motor cable and the feedback cable together for a long distance.


The best way to avoid EMI is to use good wiring hygiene during panel or machine design. Issues such as grounding, cable shielding and "wire connection" are all very important. Radio filters can also be used to limit power-conducted noise on the line, which is the worst manifestation of radio noise. Noise radiated directly from the driver is not a problem.




Electronic interference from the VFD may cause problems with other equipment in the area where the driver is installed, and other equipment may have problems in order to operate the driver correctly. The driver itself can generate interference through various frequencies and amplitudes. This may affect radio communications, instrumentation or other equipment or equipment. By carefully following the best installation practices for wiring and grounding, the possibility of problems in the application can be greatly reduced. The manufacturer's recommendations for cable selection, grounding and installation are essential to obtain good results. Generally, each wiring type should be separated from each other as much as possible. The input and output wiring of the drive should not be placed next to each other, and should also be separated from the control cable. The shielded cable between the properly installed driver and the motor will help to keep the noise inside the cable, and then the noise will have a low impedance path back to the power supply. This will greatly reduce the possibility of noise entering other cables and help prevent noise from radiating into the air. Sometimes, the noise from the VFD may return to the AC line and cause interference with other devices on the network, or may even spread through the air to interfere with other devices. In this case, it may be useful to apply a filter to suppress noise. Some VFDs can provide this protection as a standard or optional feature in the form of a filter. It is also possible to provide or specify this type of electromagnetic interference/radio frequency interference filter and apply it to the driver's input to reduce noise.


Most VFD manufacturers have two types of EMI: radiated emission and conducted emission. Most VFD manufacturers provide controls in protected and sealed metal cabinets or compartments that have been tested for radiation and immunity to external EMI. Generally, metal cabinets are designed to limit EMI and have been tested to comply with various IEC, IEEE or CE standards to determine the generation or susceptibility of EMI. All VFDs should have a certification that proves their EMI level. For the conducted emission of high-frequency components derived from the VFD through the power wire, the standard still applies, and the control system is designed to limit the conducted emission and test to meet one of the standards. Generally, some type of filter will be added to the control power connection to eliminate any conducted emissions that occur on the line due to EMI from the control system or semiconductor switch transients. The key to these two types of emissions is to ensure that the design of the VFD complies with EMI standards and has the appropriate label to indicate that it meets these standards.