How to solve the noise problem caused by inverter and motor starting
With the development and popularization of frequency converters, more and more motors need to be used with frequency converters. However, in the process of supporting the use of frequency converters and motors, many problems will inevitably be encountered. These exposed problems are more and more worthy of our thoughts and exchanges.
Recently, many customers have inquired about the buzzing noise after adding the inverter to the motor. What's the matter? In fact, the buzzing sound is caused by the carrier frequency of the output waveform of the inverter. Let us analyze the two situations of fixed carrier and automatically adjusted carrier:
1. Fixed carrier
If the frequency converter used is a fixed carrier, the motor emits a scream at this time, which stimulates the human ears. You can adjust the carrier frequency to reduce the sound. Although the higher the carrier frequency, the lower the sound, but the higher the carrier frequency, the easier the inverter will generate heat. At this time, we need to comprehensively consider the carrier frequency used according to the degree of heat generation and the sound emitted.
Two, automatically adjust the carrier
If the frequency converter used is to automatically adjust the carrier, the buzzing sound of the motor will be softer, and the sound should generally be nicer. If you don't want to accept this sound or want to run silently, you can increase the carrier frequency until you are satisfied with the sound.