How to increase the power generation of photovoltaic systems
Date: 2022/11/4Read: 38

How to increase the power generation of photovoltaic systems

Aug 12, 2021

How to increase the power generation of photovoltaic systems

If an industry depends on government subsidies to survive, then this industry will never do much. Photovoltaic subsidies will decrease year by year until the subsidies are completely eliminated. It is the general trend for photovoltaic power generation to achieve parity on the Internet. Only in this way can the photovoltaic industry move forward. In the era of subsidies for power generation, there are actually many tips on how to make electricity meters turn faster and increase investment returns. The same investment, the same lighting, a little attention when designing and installing, the results may be completely different. The author has tracked more than 1,000 distributed photovoltaic power stations in China, summed up some experience and shared with you.


The component faces south and the inverter faces north:


The module should face the sun as much as possible, the angle and direction of the maximum radiation, the installation angle is generally the local latitude plus 5 degrees, and the installation angle is generally a little bit west from the true south. The inverter is just the opposite. Try to install it on the wall on the south side. The panel of the inverter should face north and avoid sun exposure.


(1) The installation of the machine should have a suitable height from the ground to facilitate observation and reading of the LED display.


(2) When installing outdoors, install a rain-proof sun canopy on the inverter to avoid direct sunlight and rain. The inverter is not directly exposed to the sun or other heat sources.




(3) Sufficient space should be reserved for the installation and movement of the inverter. Leave at least 50cm space around the inverter below 20KW. 30KW is to enter the wind from the side, with a space of more than 100cm on both sides.


(4) There must be sufficient load-bearing capacity, which is more than 1.5 times the weight of the inverter.

(5) The cooling air duct of the inverter is air inlet from the bottom and air outlet from the top. The inverter must be installed vertically. It is strictly forbidden to install it horizontally or upside down.




(6) The inverter must be placed in a ventilated space. The inverter is divided into forced air cooling and natural heat dissipation. The inverter itself is a heat source, and all the heat must be emitted in time. A closed space, otherwise the temperature will rise higher and higher.


The wider the inverter voltage range, the higher the power generation


Jincheng City, Shanxi Province has introduced a preferential photovoltaic subsidy policy. For newly built projects in rural areas (below townships) in Jincheng City, the municipal finance will also subsidize 0.2 yuan/kWh; the initial installation subsidy is 3 yuan per watt. Attracted a large number of farmers to install photovoltaic power plants. With the increase in the amount of installation, people communicated with each other and found that the same installed capacity, the same components, and different inverters were selected, and some power generation differed by more than 10%. Why does this happen? This is because the inverter can not generate electricity with the sun, and it is also affected by the intensity of light and the voltage of the grid.


The light intensity will affect the voltage of the module. Although from the IU curve of the module, the power of the module only changes the current and the voltage does not change much, but from the actual measurement, the light intensity and temperature will affect the voltage of the module, and the range is still relatively large. , The wider the inverter DC MPPT voltage range, the higher the system power generation.


A customer in Jincheng, Shanxi Province, by observing the inverter with low power generation, found that the inverter frequently restarts, overvoltage and undervoltage alarms, and further measured the grid voltage, and found that the fluctuation range is between 185V-265V, and the grid voltage exceeds 242V. The converter will shut down. Inverters with high power generation have a wide output voltage range, so this will not happen, but widening the voltage range requires higher inverters. First, the withstand voltage of AC components will increase, and the cost will increase. Second, the related software algorithms are complicated, and some manufacturers cannot keep up with their technical capabilities. Although widening the voltage range will increase power generation, it has no effect on the power grid. The standard voltage of European TUV reaches 266V, but my country's industry standard is 242V, and manufacturers have to take certain risks. Therefore, users should choose manufacturers with a real conscience to do it.

Reduce loss


(1) The series connection voltage of the components is as high as possible. The working voltage of the 3-phase string inverter is between 650-670V, and the efficiency is the highest. Because in this voltage range, the DC-DC boost part of the early stage is directly short-circuited. The main loss of this part is gone, only the DC-AC inverter loss.


(2) The DC photovoltaic cable should be as short as possible, and the distance between the inverter and the meter should also be short.


(3) Use small-group strings for areas with poor consistency, and use large-group strings for areas with good consistency.


The number of inverters should be as small as possible. The greater the inverter power, the higher the efficiency. The efficiency of a 3KW inverter is about 96%, and the efficiency of a 30KW inverter will exceed 98%. A 500KW centralized inverter. The efficiency can reach 99%, and for photovoltaic grid-connected inverters, MPPT maximum efficiency tracking, pre-DC-DC boost, and islanding detection, there will be power loss, and all of them will bring a small amount of harmonics to the grid. From an economic point of view, a high-power inverter is cheaper per watt, has a lower installation cost, and uses less cables.

SAFESAVE's inverter products have passed various international system certifications, and have won recognition from customers with the highest quality service and quality.