How to reduce the cost of system configuration from the selection of photovoltaic inverters?
How to reduce the cost of system configuration from inverter selection? Starting with the data of an actual operating power station in Zhejiang, China, the following analysis is made.
The power station is equipped with 24 250Wp polysilicon components and a single-phase dual-channel MPPT inverter. Intercepting some parameters of the inverter shows that the rated output power of the 5K inverter is 5000W, and the maximum output power is 5500W. The total nominal power of the components is 6000Wp.
Retrieving historical monitoring data, the maximum output power of the system is 4951W.
However, the inverter can output a maximum power of 5500W. It can be seen that for the 6000Wp system in Zhejiang (the third-class resource area), this SununoPlus5K-M machine is more than enough.
Then, a series of questions came. . .
[1] Is the maximum output power the long-term output power of the machine?
[2] When configuring an inverter for a system, should the rated output power or the maximum output power prevail?
[3] How to calculate the capacity ratio of components and inverters to save costs?
Next, we quote some clauses in the national technical standards of inverters to further explore:
visible:
[1] The standard defines the maximum output power of the inverter as the power output for a long time.
[2] Since the maximum output power is long-term operating power, when configuring the system, we also recommend using the maximum output power of the inverter for component matching.
[3] Let’s take a look at this power station in Zhejiang (a third-class area). The maximum output power of the 6000Wp system is 4951W, and the ratio is about 1.2:1.
According to the package of a large household system integrator in the region, a standard household system with 24 pieces of 275Wp, with a total component power of 6600Wp, uses a SununoPlus5K-M with a maximum output power of 5500W to meet the output requirements of the system.
For a large system integrator, the use of 1.1/1.2:1 ratio to configure the system can greatly reduce the cost of system selection. Of course, this also needs to be determined according to the local solar resource conditions.