What is the fault of photovoltaic system power generation is too low
Date: 2022/11/4Read: 34

What is the fault of photovoltaic system power generation is too low

Aug 04, 2021

What is the fault of photovoltaic system power generation is too low

After the photovoltaic system is installed, the user is most concerned about the power generation, because it is directly related to the user's return on investment. There are many factors that affect power generation, such as the quality of components, inverters, cables, azimuth angle of installation, tilt angle, dust, shadow shading, component and inverter ratio system schemes, line design, construction, grid voltage, etc. Factors are possible. This series of articles will discuss various factors one by one based on actual cases. This article mainly discusses the impact of inverter failure on the system


Inverter for photovoltaic system


The photovoltaic system is composed of components, brackets, inverters, cables, power distribution cabinets and other equipment. Brackets are structural equipment and generally will not be damaged except for wind damage; modules and inverters are power generation equipment, but the power density of the modules is low. For example, a 10kW power station uses 40 modules and a total area of 64 square meters, but the energy is all Concentrated in an inverter with an area of 0.25 square meters, the inverter has a high power density and contains high temperature, high pressure and high current.


In addition, the inverter needs to deal with a lot of things. In addition to converting direct current into alternating current, it also undertakes tasks such as detecting components and grid conditions, system insulation, and external communication. The calculation is large and error-prone.


The photovoltaic inverter is composed of circuit boards, fuses, power switch tubes, inductors, relays, capacitors, display screens, fans, radiators, structural parts and other components. The service life of each component is different. The service life of the inverter can be explained by the "bucket theory". The maximum capacity of a wooden bucket is determined by the shortest wooden board, and the service life of the inverter is determined by the component with the shortest service life. , The inverter is the most prone to failure is the power switch tube, capacitor, display screen, fan and other four components.


Power switch tube


The power switch tube is the main device that converts DC to AC, and is the heart of the inverter.


At present, the power switch tubes used in inverters include IGBT, MOSET, etc., which are the most fragile components of the inverter. It has three fears: one is afraid of overvoltage, and a 600V tube withstands voltage. If the voltage at both ends exceeds 600V, it will not It will blow up in 0.1 seconds; secondly, a tube with a rated current of 50A will blow up if the current passing through is greater than 50A; thirdly, it will blow up in less than 0.2 seconds; thirdly, it will blow up if the IGBT has a low temperature of 150 Degree or 175 degrees, it is generally controlled below 120 degrees, heat dissipation design is one of the most critical technologies of the inverter.


If the power device is damaged, it means that the inverter needs to be replaced. But don't worry too much, because these factors have been considered in the design of the inverter. Under normal circumstances, there is no problem with the service life of up to 20 years. When installing the inverter, consider leaving a heat dissipation channel for the inverter. In addition, if the power grid has too high harmonics and too frequent voltage mutations, it will also cause overvoltage damage to the power devices.


Electrolytic capacitor


Capacitor is a component of energy storage and one of the indispensable components of inverter.


Capacitors include electrolytic capacitors, film capacitors, etc., each with its own characteristics, which are all required by the inverter. There are many reasons that affect the life of electrolytic capacitors, such as overvoltage, harmonic current, high temperature, rapid charging and discharging, etc. Under normal use, the biggest impact is temperature, because the higher the temperature, the faster the volatilization loss of the electrolyte. It should be noted that the temperature here does not refer to the environment or surface temperature, but refers to the working temperature of the aluminum foil.


Manufacturers usually mark the capacitor life and test temperature on the capacitor body. The volatilization of the electrolyte limits the life of the electrolytic capacitor. The Japanese NCC capacitor is one of the best capacitors in the world. .


LCD

The LCD screen of the inverter can display various indicators such as the instantaneous power, power generation, and input voltage of the photovoltaic power station. If the cause of the failure can be displayed, it will be a very useful component.


Most inverters have displays, but some do not. In addition to the above advantages, liquid crystal displays have a fatal flaw-short service life. Normal quality LCD monitors will be severely attenuated and cannot be used if they work for 30,000 to 40,000 hours. We calculate according to the inverter working hours from 6:00-20:00, the LCD monitor works 14 hours a day, 5000 hours a year. Assuming that the LCD display has a lifespan of 40,000 hours, then its lifespan is 8 years.


Nowadays, household inverters generally retain the display, and there is a trend for medium and high-power string inverters used in power stations without LCD screens.


fan


The heat dissipation methods of string inverters mainly include forced air cooling and natural cooling.


Forced air cooling requires the use of fans. Through comparison experiments of heat dissipation capacity of string inverters, it is found that the heat dissipation effect of forced air cooling is better than that of natural cooling for medium and high power string inverters. The use of forced air cooling can reduce the temperature rise of key components such as the internal capacitors and IGBTs of the inverter by about 20°C, which can ensure the long-life and high-efficiency operation of the inverter, while the inverter with natural cooling will increase the temperature and reduce the life of the components. . The lifespan of high-quality fans is about 40,000 hours. Smart cooling inverters usually start to work only when the inverter power reaches more than 30%. The average working time per day is about 4-5 hours, about 1800 hours per year, and it has not been used for 20 years. problem.


The most common fault of the fan is that the fan's power supply is broken, or foreign matter enters the fan, hindering the rotation of the fan.


Summarize


As an electronic product, the photovoltaic inverter has certain limitations in its use. Pay attention to it when designing and installing it. For experienced EPC installers, the inverter failure rate is more than 30% lower than that of inexperienced installers, so experience is very important. When transporting and installing the inverter, handle it gently to avoid loosening of the connectors inside. Temperature has a greater impact on the life of the main components of the inverter. The inverter should be installed in a ventilated place away from direct sunlight; attention should be paid to the matching of the components and the inverter, and the inverter should not work for a long time in a fully loaded state; Do not install the inverter in a grid environment with high harmonics, which can significantly reduce the probability of inverter failure and extend its service life.