-
E-mail
amy@safeinvert.com
- Phone
-
Address
#22 Liujiang Avenue, Liushi Town, Yueqing City, Zhejiang Province, China
Membership
Help
Zhejiang Saikong Electrical Technology Co., Ltd.Free·1YRS
amy@safeinvert.com
#22 Liujiang Avenue, Liushi Town, Yueqing City, Zhejiang Province, China
From single speed to variable frequency, what is the difference between different swimming pool circulating pumps?
With the promulgation of the US Department of Energy (DOE) "Special Pool Pump Energy Conservation Standards", the global swimming pool pump industry has ushered in the most turbulent point in time, and the discussion on the energy efficiency of swimming pool pumps has also risen to an unprecedented new height.
In the swimming pool, the water pump exists like a heart. Although it can circulate the water in the swimming pool through the rotation of the impeller, and then realize the filtration and treatment of the pool water and ensure the clean water quality, it is also a device that consumes more electricity. At present, swimming pool water pumps on the market include single-speed water pumps, adjustable fixed-speed water pumps, and stepless variable frequency water pumps. Some of them are born for practicality, some are born for energy saving, and there are products that coexist with practicality and energy saving, that is, the stepless variable frequency water pumps on the market today. If you are considering buying or replacing a new swimming pool pump, you may have to understand which type of swimming pool pump best meets your needs, and which type of swimming pool pump is more suitable and energy-saving.
Single-speed water pump, the initial model among swimming pool pumps
Single-speed water pumps have existed and used for decades in the swimming pool equipment industry, and their advantages and disadvantages have long been obvious.
Although this type of water pump has a wide range of applications and complete models, it can never be separated from the "energy consumption", that is, the input power and output power are not adjustable, so whether it is circulating filtration, backwashing, heating, disinfection, and waterscape special effects, once it starts to work , The motor of the single-speed water pump will run at a constant speed, supply water with the rated water output, and consume stable electrical energy. Without the intervention of the electronically controlled frequency conversion system, the input power and output efficiency cannot be adjusted reasonably. For users, whether it is energy consumption or noise, it is an unsolvable problem.
The advantages are low initial investment, economical efficiency and easy maintenance.
Adjustable fixed-speed water pump, advanced version of single-speed water pump
The adjustable fixed-speed water pump, as the name suggests, is an adjustable water pump that provides three speed options of high, medium and low speed.
This kind of water pump is an improvement of the single-speed pump, and the working mode of the single-speed pump is the same, but three different options are provided. The user selects a suitable number of revolutions for flow, head, time, etc. according to different needs, and starts using it at a fixed speed.
Compared with the single-speed pump, although the two-speed pump has higher investment in the early stage, it is also more efficient, especially when running at low speed, it can reduce energy consumption by 50% or more, and the noise will be lower. The disadvantage is that there is no continuous adjustment of electronic control and impeller efficiency. Simply reducing the speed simply and roughly cannot really adjust the speed and frequency for use.
Variable frequency pumps, the new vitality of the pump market
The variable frequency pump is a milestone product in the swimming pool pump industry. It solves the problems of high energy consumption and high noise existing in fixed frequency pumps.
The variable frequency water pump adopts the most energy-saving motor mode on the market, which means that the variable frequency water pump consumes less electric energy than a single-speed water pump at the same flow rate.
Not only that, the application of variable frequency technology allows variable frequency water pumps to change the frequency of the power supply through the variable frequency system, and adjust the speed of the pump motor in real time. It is like installing an intelligent control system for the motor, so that the head and flow rate of the pump can vary with the power supply frequency and motor speed. change.
It can be seen from fluid mechanics that the flow rate of water Q is proportional to the first power of the pump speed N, the pressure H is proportional to the square of the speed N, the power P is proportional to the cube of the speed N, and P (power) = Q (flow) × H (pressure), if the efficiency of the pump is constant, when the required flow is reduced, the speed N can be reduced proportionally, and the shaft output power P will drop in a cubic relationship at this time. Therefore, when the required flow rate Q is reduced, the output frequency of the inverter can be adjusted to reduce the motor speed n proportionally, and the power P of the motor will also be greatly reduced according to the cubic relationship, so as to achieve the purpose of saving electricity. In actual circulating filtration, the required circulating flow will inevitably change according to different operating conditions. This is the main reason why variable frequency water pumps will become the best energy-saving choice.
According to the principle of similar laws of pumps, if the pump speed is reduced by half, the power consumption will be reduced to one-eighth of the original. In other words, from the perspective of power consumption, even a short-term high-speed operation will consume more power than a low-speed operation for 24 hours. Then, assuming that the cost of a single-speed pump running for 8 hours a day is 20 yuan, then the cost of a variable-frequency pump running at the same speed for 8 hours is only one-eighth, that is, 2.5 yuan. Therefore, even if the variable frequency pump runs 24 hours a day, it can save at least 60% of energy consumption. This also means that compared to fixed frequency pumps, variable frequency pumps can help swimming pool owners recover the upfront costs more quickly, making swimming pool operations more economical.
From single speed to variable frequency, what is the difference between different swimming pool circulating pumps?
Take the Fialand variable frequency water pump PFLOW G22L0 as an example, a 60m³ swimming pool needs to achieve a cycle filtration, PFLOW needs to operate at a low speed of 2.48kwh for 13.8 hours, while a fixed frequency pump needs to operate at a high speed of 8.2kwh for 5.19 hours . Combined with the head to calculate the annual power consumption, it is not difficult to calculate that PFLOW can save at least 70% of the energy consumption per year compared to the fixed frequency pump.
From single speed to variable frequency, what is the difference between different swimming pool circulating pumps?
In terms of noise, the mute noise reduction effect of variable frequency pumps is also well known. During the operation of the pump, there are many factors that affect the noise volume, such as the speed of the motor when it is running, the size of the pipeline pressure, the speed of the water flow, and the vibration of the system. The frequency conversion pump uses the frequency conversion technology to control the system to adjust the speed, so that the water pump always runs at a relatively efficient low speed, that is, low frequency and low speed operation. This low speed can significantly reduce the noise of the motor during operation, especially at night or other low-flow operation, the motor's running noise, water flow noise and system vibration noise will be minimized, and the mute noise reduction effect is particularly obvious.
Also take Fiarland PFLOW as an example. This product is equipped with self-developed full DC frequency conversion technology, with a noise level as low as 36.6dB(A), and it sounds like a whisper in a quiet library at a distance of 1m. Generally, noise control is outstanding.
From single speed to variable frequency, what is the difference between different swimming pool circulating pumps?
On the other hand, due to the long-term operation in the medium and low frequency, the parts of the variable frequency pump have a lower ratio of wear and daily energy consumption, and the service life of the pump is also longer. The advantages of energy saving and environmental protection are outstanding.
Nowadays, with the development of technology and the continuous improvement of energy efficiency standards, the development of swimming pool pumps from fixed frequency to variable frequency is an inevitable trend of industrial development. From the overall advancement of the national energy conservation and environmental protection policy to the green development trend of the pump industry, it indicates that variable frequency pumps will be the mainstream of the future market, and once they become popular, they will surely usher in explosive growth.
Variable frequency pumps not only refresh consumers' expectations for high performance, low energy consumption and low noise, but also have the potential to occupy the mainstream of the swimming pool pump market with lower operating costs and higher economic return. From a long-term perspective, the subsequent use of single-speed water pumps and adjustable fixed-speed water pumps will bring high energy consumption and higher maintenance costs, which will gradually discourage consumers. Especially after the formal promulgation and implementation of the new DOE regulations, a large part of high-efficiency fixed-frequency water pumps will become potential obsolete products. In this view, more energy-saving and efficient variable frequency pump products will soon become the main choice in the market.