How to install photovoltaics on complex roofs?
In recent years, with the increasing maturity of the photovoltaic market and the continuous advancement of industrial and commercial photovoltaics, more and more factory roofs are equipped with photovoltaics and use clean energy. However, large, flat, well-oriented, unobstructed cement or color steel roof resources are becoming less and less, and the remaining undeveloped may be complex roofs with multiple structures such as multiple angles, multiple orientations, and shelters. . Faced with increasingly complex roof resources, how to design photovoltaic power plants on these complex roofs? It is the most concerned issue of every photovoltaic designer and investor to control the cost and ensure the power generation, but also to be safe and reliable.
01-Multi-angle and multi-directional roof
According to the basic principle of circuit series, in the same loop, the current is determined by the smallest component, which is the well-known principle of the barrel effect. Therefore, when designing the strings, the component model, installation angle, and number of strings of each loop of each inverter should be kept as consistent as possible. Each MPPT loop of the inverter runs independently and does not interfere with each other, so different MPPT loops can be different.
When facing a roof with a complex structure, you can select multiple inverters or multiple MPPT inverters based on the number of locally consistent components. At present, the inverter technology is very mature, and the harmonic suppression problem of multiple inverters in parallel has been solved. Inverters of different powers are combined together on the grid side without any problems. In projects with larger photovoltaic power, you can choose an inverter with high single-unit power and multiple MPPTs to further reduce the series-parallel mismatch loss of modules under complex roof conditions.
10-channel MPPT design to minimize string mismatch loss
In some more complex scenarios, three-phase grid-connected and single-phase grid-connected may occur at the same time. In this case, three-phase inverters and single-phase inverters can also be combined. According to the current national standard "Design Specification for Low-Voltage Power Distribution", there are three forms of low-voltage power distribution systems, namely IT systems, TT systems, and TN systems. Among them, the IT system does not have a neutral line, and the TT system and TN system have a neutral line. In the industrial, commercial and civil systems, most of them are TN systems. The grid-connected inverter is connected to the grid, the three-phase inverter is three-phase five-wire, and the single-phase inverter is a live wire, a neutral wire and a ground wire. Therefore, when there are three-phase and single-phase, they are connected to the grid. In the scenario, there is no problem with the electrical connection.
★Note: When single-phase inverters are connected to the three-phase power grid, pay attention to the problem of three-phase unbalance. Therefore, try to connect the single-phase inverter to the phase with the largest load. If it is a single-phase inverter, Then try to evenly distribute and connect to the three phases.
02-Roof covered by shadows
The shadows of photovoltaic power plants can be divided into temporary shadows, environmental shadows and system shadows. Many factors can cause temporary shadows on the photovoltaic array, such as snow, fallen leaves, bird droppings, and other forms of pollutants; generally, the inclination angle of photovoltaic modules greater than 12° is more beneficial to the self-cleaning of the photovoltaic array.
The shadow of the system itself is mainly the occlusion of the front and rear of the module. The array spacing can be calculated according to the installation inclination and the size of the module during the design to ensure that it will not be occluded from 9:00 to 15:00 on the winter solstice day.
During the construction of photovoltaic power stations, environmental shadows are more common. Tall buildings, gas towers, roof height differences or trees around the floor will shadow photovoltaic modules, which will cause the loss of photovoltaic string power generation. If the installation conditions are restricted and solar modules have to be installed in shaded places, the following methods can be adopted to minimize losses:
(1) The solar radiation is the strongest around noon every day, and the power generation between 10 am and 15 am accounts for more than 80%, and the light in the morning and evening is weaker. You can adjust the installation angle of the components to try to avoid the shadows during the peak hours of electricity development. , This can reduce a part of the loss.
(2) Let the components that may have shadows be concentrated on an inverter or on an MPPT loop, so that the shadowed components will not affect the normal components.
03-The installation inclination angle is not the best housing item
The installation angle of photovoltaic modules includes two angles: inclination and azimuth. Inclination angle (elevation angle): the angle between the photovoltaic module and the horizontal ground. Azimuth angle: the angle between the orientation of the photovoltaic module and the true south direction. Whether it is the change of the inclination angle or the change of the azimuth angle, it will affect the power generation of the photovoltaic project.
Assuming that the efficiency of the module is 99% at the optimal installation angle, if the inclination angle is not correct, the power loss will be relatively large, for example, the efficiency is only 59% when installed vertically. For a photovoltaic square array slope, the difference in the incident angle of the sun on it will result in a different amount of solar normal radiation received per unit area, and the installation inclination of the photovoltaic square array will change the incident angle of the sun. This affects its radiation reception, which in turn leads to a decrease in component power generation.
For cement-floor workshops, most of the optimal inclination angles can be used for array design. According to previous engineering experience, the optimal installation inclination angle is generally less than 5°~10° of the local latitude.
For industrial color steel plants, the inclination angle of color steel tiles is generally only about 10 degrees. If photovoltaic modules are installed at this angle, the overall efficiency is relatively low and the loss is relatively large. If conditions permit, the color steel tiles with angle solar mounts can be used. Appropriately increase the installation angle to improve the efficiency of the photovoltaic system. However, when designing, pay attention to several points: In coastal areas, pay attention to typhoons, because the increase in angle will produce negative wind pressure, and the wind-resistant design of the support must exceed the strongest local typhoon load; in northern areas, pay attention to the accumulation of wind pressure. The influence of snow requires calculation of snow load and design of snow melting channel.
04-Roofs with insufficient load-bearing capacity
At present, there are several difficulties in industrial and commercial projects: the roofs of some companies with good benefits may be relatively old, and the floor can not meet the load-bearing requirements. The installation of photovoltaics requires separate reinforcement of the roof, which increases a lot of costs; some airports, shopping malls and other roofs are all glass Top, the owner wants to install photovoltaics without destroying the previous glass structure. How to solve the pain points of this type of roof installation?
BIPV modules currently on the market can solve this problem. From the perspective of building load restrictions and installation difficulty restrictions, BIPV modules have more stringent requirements for light weight and flexibility. Lower weight can minimize the load-bearing pressure of the building, and its own weight is much lower than conventional modules. Some are only one-fourth of the weight of conventional modules, which can effectively reduce the load limit of old floors and are suitable for installation on roofs with insufficient load-bearing capacity. The component and the color steel tile are connected by building structural glue instead of the traditional fixed bracket, which can reduce the overall cost of the system by more than 20%. It can also be used for glass roofs, which can be glued on with structural glue, which is easy to install and does not add additional load-bearing capacity.
In the context of increasingly stringent carbon emission control and increasing social power demand, more and more companies have begun to participate in the construction of industrial and commercial photovoltaic projects, but good roof resources are always limited, facing increasingly complex photovoltaics On the roof, we can solve the problem of photovoltaic installation on complex roofs from various aspects such as equipment selection and system design, so that more and more owners can use clean energy.