The MIC-600 fixed two-in-one gas detection and alarm instrument is used for 24-hour continuous online monitoring and temperature and humidity measurement of various gas concentrations in the field, the concentration is displayed on the spot and the over-standard sound and light alarm, and remote data transmission. The 2.5-inch high-definition color screen displays the concentration in real time. According to different detected gases, the best brands of electrochemical, infrared, catalytic combustion, thermal conduc......
Details
Features of MIC-600 fixed two-in-one gas detection alarm:
●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceeding national standards, resistance to high-intensity pulse surge current impact. High reliability and stability. Anti-reverse design, any form of reverse connection will not damage the instrument
●It complies with EMI and EMC standards, and has passed national standard testing and CMC measurement instrument license certification.
Executive standard: GB15322.1-2003
GB 3836.1—2010 "General Requirements for Electrical Equipment for Explosive Gas Atmospheres"
GB 3836.2—2010 "Electrical Equipment for Explosive Gas Environment Explosion-proof Type "d""
GB 3836.4—2010 "Electrical Equipment for Explosive Gas Environment Intrinsically Safe "i""
●Standard bus RS485 (RTU) and 4-20mA standard signal output at the same time, 3 groups of relay switch output, on-site sound and light alarm. Optional frequency output 200-1000Hz, Hart protocol signal, 1~5V output, wireless transmission (2~5km or unlimited distance). Wired or wireless remote real-time monitoring can be performed. Data can be uploaded to a phone or transmitted to the Environmental Protection Agency, other monitoring centers, monitoring equipment, and monitoring computers via a local area network or the Internet. The concentration of the site can be monitored in real time through free upper computer software or gas alarm controllers.
●Compatible with various secondary meters, data acquisition modules, PLC, DCS systems, can directly drive solenoid valves, fans, detectors and other equipment, and can also drive high-power equipment by driving intermediate relays. Optional MIC2000 controller can monitor 1000 detectors at the same time.
●Large-capacity data storage function, can record real-time concentration value, temperature and humidity, or only alarm value and time. Support local storage or SD card storage. The standard storage capacity of this machine is 100,000 records. If a larger capacity is required, please indicate when ordering. SD card storage capacity can be customized. Data export and analysis through free upper computer software, support on this machine.
To view data or delete data, it can be set to automatically overwrite data or not to overwrite data when the capacity is insufficient, and automatically stop the recording function.
●The standard infrared remote control can realize the operation without opening the cover in dangerous situations, such as: modify the alarm point, concentration calibration, zero point calibration, silence, restore the factory, enter the menu, view the record, 4mA output, 20mA output (calibrate other acquisition equipment) This function is required).
●Chinese and English interface can be selected, the default Chinese interface, support free switching of gas concentration units, conventional gas does not need to enter the molecular weight, and the molecular weight of special gas is automatically calculated and switched after entering the molecular weight. The units are optional: PPM, mg/m3, Vol%, LEL% , PPHM, ppb, mg/L
●The 2.5-inch high-definition color screen (LCM) displays real-time concentration, time, temperature, humidity, storage status and other information. It can detect 4-6 gas concentrations and temperature and humidity at the same time. The menu interface uses high-definition simulation icons to display the function names of each menu. Concise Chinese or English operation prompts.
●Three display modes can be switched: simultaneous display of multiple gas concentrations, large font cycle display of single channel gas concentration, real-time curve, automatic or manual cycle between channels can be switched, you can set whether to display the maximum value, minimum value, gas name , You can view the historical record graph.
●Automatically track the zero point to prevent drift, temperature compensation, multi-level calibration, which can simultaneously meet the national standard and the standards of the local and provincial metrology bureaus in various regions
●Data recovery function, automatic identification and prevention of incorrect operation of concentration calibration, which can avoid defects caused by improper operation.
●Can record calibration log, maintenance log, troubleshooting countermeasures, reminder of the expiration of sensor life, reminder of the next concentration calibration time
Parameter
MIC-600 fixed two-in-one gas detection and alarm instrument parameters:
Detection gas: composite gas (carbon monoxide CO, oxygen O2),
Optional: It can detect any 4-6 kinds of gases and temperature and humidity at most at the same time
Detection range: CO (0~1000ppm), O2 (0~30%Vol), other ranges can be customized
Resolution: CO (0.1ppm), O2 (0.01%Vol), higher resolution can be customized
Detection principle: electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoion, according to gas, range, site environment and user needs
Sensor life: 2 to 3 years for electrochemical principle, 2 or 6 years for oxygen, 5 to 10 years for infrared principle, 3 years for catalytic combustion, 5 years for thermal conductivity
Temperature detection: -40℃~+120℃ (optional), humidity detection: 0~99%RH (optional), resolution: temperature 0.1℃, humidity: 1%RH
Detection accuracy: ≤±2%F.S (≤2% in full range), temperature 0.5℃, humidity: 3%RH, higher precision can be customized
Working mode: fixed installation, online detection, diffusion measurement, pipeline type, flow type, pump suction type optional
Installation method: pipeline type, wall-mounted type. The working pressure of the pipeline type is ±30% of atmospheric pressure, and the pressure needs to be reduced if it exceeds the range
Response time: T90≤20 seconds
Recovery time: ≤30 seconds
Output signal: bus system RS485 (RTU), optional three (four) wire system 4~20mA, 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission
Alarm mode: on-site acousto-optic alarm (optional), default 1 channel, optional 3 passive contact (dry node) output, three-level alarm, alarm point can be set
Working environment: -40℃~+70℃
Sample gas temperature: -40℃~+70℃ (normal), optional: -40℃~+400℃, -40℃~+800℃ (maximum 1300℃)
Relative humidity: ≤10-95%RH (conventional) non-condensing occasions, optional: 10-99%RH for high-temperature and high-humidity occasions, need to be noted when ordering, pretreatment system is required)
Working voltage: 12~36V (DC DC, the standard power supply of a single device is 24V, 1A or DC switching power supply greater than 1A)
Power reference: 24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors
Explosion-proof form: flameproof type ExdⅡCT6
Connecting cable: 4~20mA select three-core shielded cable, RS485 select four-core, single wire diameter ≥1.5mm when the distance exceeds 1000 meters; the shielding layer is connected to the ground
Electrical interface: 3/4NPT, optional M20X1.5 internal thread, 1/2NPT
Protection level: IP66 waterproof and short-term rain, long-term rain needs to be equipped with a rain cover or choose a shell without display or specify when ordering
Dimensions:
260×180×90mm (L×H×W) atmospheric chamber
260×230×90mm(L×H×W) atmospheric chamber with light
240×180×90mm (L×H×W) conventional air chamber
240×230×90mm(L×H×W) conventional with light
Weight: 1.8Kg
Optional accessories: wall mounting brackets, mounting brackets fixed on the pipe (four points, six points), DN50 flanged pipe installation or stainless steel threaded welding seat (the pipe size needs to be indicated, such as DN50, DN15...), normal temperature High humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature, high humidity and high dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large capacity SD memory card, rain cover, 24VDC or 220AC sampling pump (sampling Distance 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switching power supply.
Accessories needed for computer monitoring: free PC software, RS485/RS232 converter, notebook computers without RS232 interface also need USB/RS232 conversion cable, if you want network transmission, you also need a TCP/IP converter
Application
Application occasions: petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions that require fixed installation and online gas concentration detection.