Welcome Customer !

Membership

Beijing Zetron Technology Co., Ltd
Free Member ·1YRS
Other

Main Products: 气体检测仪

Xwboo>Products
Product Categories

Beijing Zetron Technology Co., LtdFree·1YRS

  • E-mail

    info@bjzetron.com

  • Phone

  • Address

Contact Now

MIC2000 gas control alarm

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
The gas alarm controller is a centralized alarm controller for gas concentration monitoring and leakage. The power supply is directly supplied by the mains power grid or the storage battery. This alarm controller receives RS485 signal and 4-20mA, temporarily can only receive the RS485 signal output by our company\'s new online detector. If you need to connect to the standard RS485 signal of other manufacturers, please contact our company for confirmation. A gas alarm controller can be connected to 120 bus RS485 out......
Product Details

Details

Features of MIC2000 gas control alarm:

●3.5-inch high-definition color screen display, Chinese and English operation interface can be switched (default Chinese interface).
●It can be connected to 4-20mA signals such as various gas detectors, temperature and humidity transmitters, pressure transmitters, wind speed transmitters, dust detectors, etc.
●Optional units: PPM, LEL%, Vol%, mg/m3, ug/L, PPHM, ℃, RH%, Pa, kg, PSI, m/s
●4-20mA and RS485 can be input at the same time; data output supports standard MODBUS protocol options: 8 4-20mA output, Ethernet module, PC monitoring software, RS485/RS232 converter, USB-RS232 connection line (no serial port (The computer needs to be equipped with this option)
●Modular structure design, the standard channel is 1 (up to 32) 4-20mA input signals, and 255 RS485 input signals can be connected at the same time. More channels of input signals can be customized, and the controller and the controller can communicate with each other .
●The gas alarm controller has a data recording function, standard large-capacity transmission and storage, and larger capacity can be customized. The storage time interval can be set arbitrarily, recording time, concentration value, alarm information, etc., can be set to record real-time concentration or only alarm information, the default setting is to record only alarm information. Support local viewing of all records, selective viewing of records, and deletion of records.
●Three display modes can be switched: each screen displays 6-channel concentration, large fonts cyclically display single-channel concentration, real-time curve, automatic cycle or manual cycle between channels can be switched, and you can set whether to display maximum, minimum, gas Name, you can view the history curve graph.
●The gas alarm controller is connected to the computer monitoring function, which can be connected to the computer to continuously monitor the real-time concentration through the upper computer software for 24 hours, automatically store data on the computer, computer alarm (speaker required), or read a probe or through the upper computer software All the records stored in the probe and data analysis can display the maximum value, minimum value, average value, historical curve, real-time curve and other functions, and data can be exported or printed
●Remote transmission function of the gas alarm controller, the controller can wire the real-time concentration of the field probe (within 2000 meters).
Optional Ethernet transmission or wireless transmission function (2 kilometers, 5 kilometers, unlimited distance optional), upload data to the monitoring center, environmental protection bureau, Other monitoring equipment, and then through the host computer software for data display, storage, analysis, or use the communication protocol to customize the read data.

Parameter

Technical parameters of MIC2000 gas control alarm:

Signal input: 1~32 channels 4~20mA, RS485 input at the same time, 255 probes can be connected
Output signal: Ethernet, RS485 (standard MODBUS protocol), 4-20mA (4 channels, 8 channels optional)
Display range: number 0~99999
Resolution: 1, 0.1, 0.01, 0.001 optional
Display accuracy: ±0.1%FS
Display mode: high-definition color screen, six-channel simultaneous display or large-font single-channel circular display, more than six channels automatically or manually turn the screen and circular display
Control loop: standard is 4 channels, 1 public output, optional 8 channels, 12 channels, 16 channels control output
Alarm mode: sound and light alarm, three-level alarm, each loop can set high and low limit alarm value separately
Output control: The standard is 4 groups of relay contact output (normally open/normally closed), contact capacity 3A, 32VDC or 3A, 220VAC, one set of common alarm output, contact capacity 12A, 32VDC or 7A, 240VAC
Automatic detection: line break/short circuit detection, various detector states, function detection, etc.
Working temperature: -40℃~+70℃
Relative humidity: 0~95%RH, used in non-condensing occasions, waterproof splash and short-term rain, can be customized outdoor completely moisture-proof and rain-proof
Power source: 220VAC/50Hz or 24VDC, 2A, 24VDC, 5A, 24VDC, 10A optional, according to the number of probes to choose
Maximum power consumption: 2.5W/channel
Backup power supply: DC24V 5Ah (optional)
Dimensions: 330*255*95mm (2/4/8 channels); 420*305*95mm (16/24 channels); 540*305*95 (32 channels)

Application

Sorry  There is no "Application", you can view other services。