Zetron Best Selling MS600 Portable Six-in-One Toxic and Harmful Multi Gas Alarm

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
The MS600 measures up to 8 gases, including toxic, flammable gases and vapors, and oxygen all at once—either in pump or diffusion mode. Innovative signaling design and handy wizard functions ensure complete safety throughout the process.
Product Details

Details

MS600 Portable Six-In-One

Toxic and Harmful Gas Detector

MS600 Series Portable Composite Gas Detector can be used in: rapid and accurate detection of a variety of gas concentration and measurement of environmental temperature and humidity, if the measurement exceeded the limit value, the alarm will sound.
It adopted advanced electric circuit design, mature kernel algorithm processing, unique external appearance design, had achieved a number of patents about the software works, external appearance, and so on. 

It is possible to simultaneously detect 1 ~ 6 types of gases, and the units can be switched freely. The types for detection are more than 500 types.





Parameter

Gases to be detected
Arbitrary combination of 1 ~ 6 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.Optional configuration: temperature and humidity measurements.
Application scenarios
All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range
0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 99%LEL, 20%, 50%, 99%Vol, can be selected; and other ranges can be customized.
Resolution
0.01ppm or 0.001ppm (0 ~ 10 ppm);
0.01ppm (0 ~ 100 ppm),
0.1ppm (0 ~ 1000 ppm),
1ppm (0 ~ 10000 ppm or more),
0.01 mg/l (0 ~ 200 mg/l),
0.1% LEL,
0.01%LEL
0.001% Vol
Detection principle
Electrochemical, catalytic combustion, infrared, thermal conductivity,
PID photoionization, and so on.
Depending on the type of gas, range, field environment and user demand.
Sensor service life
Electrochemical principle: 2 ~ 3 years;
Oxygen gas: 2 years or 6 years can be selected;
Infrared principle: 5 ~ 10 years;
Catalytic combustion: 3 years;
Thermal conductivity: 5 years;
PID photoionization: 2 ~ 3 years.
Allowable error
≤±1% F.S (other precision levels can be customized)
Linearity
≤±1%
Repeatability
≤±1%
Uncertainty
≤±1%
Response time
T90≤20 seconds
Recovery time
≤30 seconds
Working environment
Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment.
Sample gas temperature
-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 1300 ℃.
Temperature and humidity measurement
Optional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 99% RH, precision level at 3 % RH
Power supply
3.6VDC, 6000mA high capacity rechargeable polymer battery
Display mode
2.5-inch high-definition color screen
Detection mode
Built-in pump-suction type measurement, and flow rate at 500 ml / min. Calibration flow rate should be greater than 500 ml / min,
three-way pipe should be connected, so as to ensure that the excessive gas will be discharged from the bypass
Alarm mode
It is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interface
USB (charging and communication), optional: RS232, infrared communication, automatic recognition
Data storage
Standard configuration is the data storage capacity for 100, 000 entries; SD card storage function is optional configuration
Protection level
IP67
Explosion-proof type
Intrinsically safe type
Explosion-proof mark
Exia II CT6
Exterior dimensions
180×78×33mm (L×W×H)
Weight
350g
Standard accessories
Manual, qualification certificate, warranty card, USB charger (including the data cable), high-grade aluminum instrument case, belt clip, humidity dust filter
Optional items
1)Temperature and humidity measurement function
2)1.2 m retractable sampling handle (1-10 meter hose, and the standard length is 1meter)
3) 0.4 meter stainless steel sampling handle (with dust filter, not retractable), 4) high temperature sampling and cooling filter handle
5) high temperature humidity pretreatment system

Application

All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.