The TKP online total phosphorus automatic analyzer is heated to 120℃ by a mixture of water sample, catalyst solution and strong oxidant digestion solution. Polyphosphate and other phosphorus-containing compounds in the water sample are digested by strong oxidant under acidic conditions of high temperature and high pressure. Oxidation generates phosphate. In the presence of a catalyst, the phosphate ion forms a colored complex in a strong acid solution containing molybdate. The analyzer detects the color change and ......
Details
Performance characteristics:
1. Select valve components: select reagent sampling sequence, flexible and diverse channels, variable functions, easy maintenance and long life.
2. With printing function, it can be connected to a printer (optional) to print the measured data in time.
3. It adopts 7-inch touch screen and simple operation interface, which can make it easy for users to learn, operate and maintain.
4. The large data storage capacity realizes the preservation of historical data of no less than 5 years (measurement interval is 1 time/1h), which greatly meets the needs of customers.
5. Automatic leakage alarm function. When reagent leakage occurs, the instrument will automatically alarm to remind the user to perform maintenance.
6. Quantitative use of light signal recognition function to ensure high accuracy of quantification.
7. The maintenance of chemical reagents is simple and convenient, and the reagents are replaced once a month, which greatly reduces the user's maintenance workload.
8. U disk one-key upgrade, software update easier.
Parameter
Method basis: phosphomolybdenum blue method spectrophotometric detection
Measuring range: 0-10 mg/L total phosphorus (divided into 0.1-2.0mg/L; 0.2-5.0mg/L; 0.5-10.0mg/L;) 10-500 mg/L total phosphorus (expansion required)
Accuracy: not more than ±10% or not more than ±0.2mg/L
Repeatability: not more than ±5% or not more than ±0.2mg/L
Measurement period: The minimum measurement period is 30 minutes. According to the site environment, the color rendering time can be modified arbitrarily from 5 to 120 minutes
Sampling period: time interval (10~9999min arbitrarily adjustable) and whole point measurement mode
Calibration cycle: adjustable at any interval from 1 to 99 days
Maintenance cycle: generally once a month, about 30 minutes each time
Output: 2 RS-232; 1 4~20mA
Environmental requirements: indoor with adjustable temperature, recommended temperature +5~28℃; humidity ≤90% (no condensation)
Power supply: AC220±10% V, 50±10% Hz, 5A