Welcome Customer !

Membership

Beijing Zetron Technology Co., Ltd
Free Member ·1YRS
Other

Main Products: 气体检测仪

Xwboo>Products
Product Categories

Beijing Zetron Technology Co., LtdFree·1YRS

  • E-mail

    info@bjzetron.com

  • Phone

  • Address

Contact Now

Online benzene detection alarm MIC-600-C6H6-A

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
MIC-600 on-line benzene detection alarm is used for 24-hour continuous online monitoring of benzene gas concentration and temperature and humidity measurement, on-site display of concentration and over-standard sound and light alarm, remote data transmission. The 2.5-inch high-definition color screen is used to display the concentration in real time. According to different detected gases, the best brands of electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoion principle gas sensors and......
Product Details

Details

Features of MIC-600 online benzene detection alarm:


●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceeding national standards, resistance to high-intensity pulse surge current impact. High reliability and stability. Anti-reverse design, any form of reverse connection will not damage the instrument


●It complies with EMI and EMC standards, and has passed national standard testing and CMC measurement instrument license certification.


Executive standard: GB15322.1-2003


GB 3836.1—2010 "General Requirements for Electrical Equipment for Explosive Gas Atmospheres"


GB 3836.2—2010 "Electrical Equipment for Explosive Gas Environment Explosion-proof Type "d""


GB 3836.4—2010 "Electrical Equipment for Explosive Gas Environment Intrinsically Safe "i""


●Standard bus RS485 (RTU) and 4-20mA standard signal output at the same time, 3 groups of relay switch output, on-site sound and light alarm. Optional frequency output 200-1000Hz, Hart protocol signal, 1~5V output, wireless transmission (2~5km or unlimited distance). Wired or wireless remote real-time monitoring can be performed. Data can be uploaded to a phone or transmitted to the Environmental Protection Agency, other monitoring centers, monitoring equipment, and monitoring computers via a local area network or the Internet. The concentration of the site can be monitored in real time through free upper computer software or gas alarm controllers.


●Compatible with various secondary meters, data acquisition modules, PLC, DCS systems, can directly drive solenoid valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays. Optional MIC2000 controller can monitor 1000 detectors at the same time.


●Large-capacity data storage function, can record real-time concentration value, temperature and humidity, or only alarm value and time. Support local storage or SD card storage. The standard storage capacity of this machine is 100,000 records. If a larger capacity is required, please indicate when ordering. SD card storage capacity can be customized. Data export and analysis are carried out through the free upper computer software, and data can be viewed or deleted on the machine. It can be set to automatically overwrite data or not to overwrite data when the capacity is insufficient, and automatically stop recording.


●The standard infrared remote control can realize the operation without opening the cover in dangerous situations, such as: modify the alarm point, concentration calibration, zero point calibration, silence, restore the factory, enter the menu, view the record, 4mA output, 20mA output (calibrate other acquisition equipment) This function is required).


●Chinese and English interface can be selected, the default Chinese interface, support free switching of gas concentration units, conventional gas does not need to enter the molecular weight, and the molecular weight of special gas is automatically calculated and switched after entering the molecular weight. The units are optional: PPM, mg/m3, Vol%, LEL% , PPHM, ppb, mg/L


●The 2.5-inch high-definition color screen (LCM) displays real-time concentration, time, temperature, humidity, storage status and other information, and can simultaneously detect 1 to 6 gas concentrations and temperature and humidity. The menu interface uses high-definition simulation icons to display the function names of each menu , Concise Chinese or English operation prompts.


●Three display modes can be switched: simultaneous display of multiple gas concentrations, large font cycle display of single channel gas concentration, real-time curve, automatic or manual cycle between channels can be switched, you can set whether to display the maximum value, minimum value, gas name , You can view the historical record graph.


●Automatically track the zero point to prevent drift, temperature compensation, multi-level calibration, which can simultaneously meet the national standard and the standards of the local and provincial metrology bureaus in various regions


●Data recovery function, automatic identification and prevention of incorrect operation of concentration calibration, which can avoid defects caused by improper operation.


●Can record calibration log, maintenance log, troubleshooting countermeasures, reminder of the expiration of sensor life, reminder of the next concentration calibration time

Parameter

MIC-600 online benzene detection alarm parameters:


Detecting gas: benzene (C6H6), optional: at most 4 to 6 gas concentrations and temperature and humidity can be detected at the same time


Detection principle: electrochemistry, infrared, thermal conductivity, PID photoion, catalytic combustion, depending on gas type, range, site environment and user needs


Sensor life: 2 to 3 years for electrochemical principle, 2 or 6 years for oxygen, 5 to 10 years for infrared, 3 years for catalytic combustion, 5 years for thermal conductivity, 2 years for PID


Detection range: 0~10ppm, 100, 1000, 2000, 5000, 10000, 99% LEL, 99% Vol optional, other ranges can be customized


Resolution: 0.01ppm or 0.001ppm (0~10 ppm); 0.01ppm (0~100 ppm), 0.1ppm (0~1000 ppm), 1ppm (over 0~1000 ppm), 0.1%LEL (0~99%) LEL), 0.01%Vol or 0.001%Vol (0~99.999%Vol)


Temperature detection: -40℃~+120℃ (optional), humidity detection: 0~99%RH (optional), resolution: temperature 0.1℃, humidity: 1%RH


Detection accuracy: ≤±2%F.S (2% within the full range), temperature 0.5℃, humidity: 3%RH, higher precision can be customized


Working mode: fixed installation, online detection, diffusion measurement, pipeline type (M45X1.5 external thread), flow type, pump suction type optional


Installation method: pipeline type, wall-mounted type. The working pressure of the pipeline type is ±30% of atmospheric pressure, and the pressure needs to be reduced if it exceeds the range


Response time: T90≤20 seconds


Recovery time: ≤30 seconds


Output signal: bus system RS485 (RTU), three (four) wire system 4~20mA, optional 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission


Alarm mode: on-site acousto-optic alarm (optional), default 1 channel, optional 3 passive contact (dry node) output, three-level alarm, alarm point can be set


Working environment: -40℃~+70℃


Sample gas temperature: -40℃~+70℃ (normal), optional: -40℃~+400℃, -40℃~+800℃ (maximum 1300℃)


Relative humidity: ≤10-95%RH (conventional) non-condensing occasions, optional: 10-99%RH for high temperature and high humidity occasions, when ordering


(Need to indicate, need to be equipped with pretreatment system)


Working voltage: 12~36V (DC DC, the standard power supply of a single device is 24V, 1A or DC switching power supply greater than 1A)


Power reference: 24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors


Explosion-proof form: flameproof type ExdⅡCT6


Connecting cable: 4~20mA select three-core shielded cable, RS485 select four-core, single wire diameter ≥1.5mm when the distance exceeds 1000 meters; the shielding layer is connected to the ground


Electrical interface: 3/4NPT, optional M20X1.5 internal thread, 1/2NPT


Protection level: IP66 waterproof and short-term rain, long-term rain needs to be equipped with a rain cover or choose a shell without display or specify when ordering


Dimensions:


260×180×90mm(L×H×W) atmospheric chamber


260×230×90mm(L×H×W) atmospheric chamber with light


240×180×90mm (L×H×W) conventional air chamber


240×230×90mm(L×H×W) conventional with light


Weight: 1.8Kg


Optional accessories: wall mounting brackets, mounting brackets fixed on the pipe (four points, six points), DN50 flanged pipe installation or stainless steel threaded welding seat (the pipe size needs to be indicated, such as DN50, DN15...), normal temperature High humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature, high humidity and high dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large capacity SD memory card, rain cover, 24VDC or 220AC sampling pump (sampling Distance 10 meters), vacuum pump (sampling distance greater than 40 meters), 24V switching power supply.


Accessories needed for computer monitoring: free PC software, RS485/RS232 converter, notebook computers without RS232 interface also need USB/RS232 conversion cable, if you want network transmission, you also need a TCP/IP converter


Application occasions: petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions that require fixed installation and online gas concentration detection

Application

Sorry  There is no "Application", you can view other services。