Welcome Customer !

Membership

Beijing Zetron Technology Co., Ltd
Free Member ·1YRS
Other

Main Products: 气体检测仪

Xwboo>Products
Product Categories

Beijing Zetron Technology Co., LtdFree·1YRS

  • E-mail

    info@bjzetron.com

  • Phone

  • Address

Contact Now

Fixed composite gas detection alarm MIC-600

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
The MIC-600 series online composite gas detector is used for: 24-hour continuous online monitoring of the concentration of various gases on site, temperature and humidity measurement, on-site concentration display, over-standard sound and light alarm (optional), and remote signal transmission. It adopts 2.5-inch high-definition color screen for real-time display, and adopts gas sensors of internationally renowned brands. The main detection principles are: electrochemical, infrared, catalytic combustion, thermal con......
Product Details

Details

Features of MIC-600 online composite gas detector:


★ It can detect 1 to 6 kinds of gases at the same time, and the unit can be switched freely.


★ Diversified communication methods.


Real-time monitoring can be carried out through wired or wireless remote transmission and network transmission; standard bus RS485 (modbus-RTU) and 4-20mA standard signal output at the same time; optional frequency output 200-1000Hz, Hart protocol signal, 1 ~ 5V output, wireless transmission (2 ~ 5 kilometers or unlimited distance); Compatible with secondary instruments, data acquisition modules, PLC, DCS systems, and can drive related equipment. Optional MIC2000 controller can monitor 1000 detectors at the same time.


★ Infrared remote control.


The standard infrared remote control is equipped with one-button operation through the function keys of the infrared remote control, which can realize the operation without opening the cover in dangerous situations, such as: modify the alarm point, concentration calibration, zero point calibration, silence, restore the factory and other functions.


★ Rich man-machine interface.


The 2.5-inch high-definition color screen displays real-time concentration, alarm, time, temperature, humidity, storage and other information; the menu interface uses high-definition simulation graphics to display the function names of each menu.


★ Large-capacity data storage function, supports multiple storage methods.


Standard configuration of 100,000 data storage capacity; optional SD card storage function, supports real-time storage, timing storage, or only alarm concentration data; supports local viewing and deleting of data, and can also be uploaded to the computer through the RS485 interface for data analysis Or print.


★ High temperature gas detection (optional).


Optional high temperature sampling cooling filter handle or high temperature and high humidity pretreatment system can detect flue gas with a temperature of 1300 degrees. Gas detection at other temperatures can be customized.


★ Three display modes can be switched.


Concentrations of multiple gases are displayed at the same time, the concentration of single-channel gas is displayed in a large font cycle, and the real-time curve is displayed.


★ Graphical display, reflecting the trend of gas concentration change in a period of time in the form of a curve.


● Data recovery function, you can choose to recover partly or completely, eliminating the worries caused by misoperation.


● High-precision temperature and humidity measurement (optional).


● A variety of alarm methods, multi-directional three-dimensional indication of the alarm state when alarming. Contains: 3 groups of relay switch output, sound and light alarm, visual alarm on the display screen. The alarm types include: concentration alarm, under-voltage alarm, and fault alarm.


● Multiple alarm mode settings: low alarm, high alarm, interval alarm, weighted average alarm.


● Misoperation recognition function: Misoperation of concentration calibration is automatically identified and prevented, which can avoid defects caused by human factors.


● Zero point automatic tracking, long-term use will not be affected by zero point drift.


● Multi-level calibration of target points to ensure linearity and accuracy of measurement.


● Chinese and English interface can be selected.


● Wide operating temperature: -40~+70℃, support temperature compensation.


● Log records.


Record calibration log, maintenance log, fault record, troubleshooting countermeasures, reminder of the expiration of sensor life, reminder of the next concentration calibration time.


● Intrinsically safe circuit design, explosion-proof, with secondary lightning protection and anti-static capabilities. Meet national standards and resist the impact of high-intensity pulse surge current. With anti-reverse connection function. Comply with EMI and EMC standards.

Parameter

MIC-600 online composite gas detector parameters:


Detection gas: composite gas (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex),


Optional: Can detect any 4-6 kinds of gases and temperature and humidity at the same time


Detection range: CO (0~1000ppm), H2S (0~100ppm), O2 (0~30%Vol), Ex (0~99%LEL), other ranges can be customized


Resolution: CO (0.1ppm), H2S (0.01ppm), O2 (0.01%Vol), Ex (0.1%LEL), higher resolution can be customized


Detection principle: electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoion, according to gas, range, site environment and user needs


Sensor life: 2 to 3 years for electrochemical principle, 2 or 6 years for oxygen, 5 to 10 years for infrared principle, 3 years for catalytic combustion, 5 years for thermal conductivity


Temperature detection: -40℃~+120℃ (optional), humidity detection: 0~99%RH (optional), resolution: temperature 0.1℃, humidity: 1%RH


Detection accuracy: ≤±2%F.S (≤2% in full range), temperature 0.5℃, humidity: 3%RH, higher precision can be customized


Working mode: fixed installation, online detection, diffusion measurement, pipeline type, flow type, pump suction type optional


Installation method: pipeline type, wall-mounted type. The working pressure of the pipeline type is ±30% of atmospheric pressure, and the pressure needs to be reduced if it exceeds the range


Response time: T90≤20 seconds


Recovery time: ≤30 seconds


Output signal: bus system RS485 (RTU), optional three (four) wire system 4~20mA, 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission


Alarm mode: on-site acousto-optic alarm (optional), default 1 channel, optional 3 passive contact (dry node) output, three-level alarm, alarm point can be set


Working environment: -40℃~+70℃


Sample gas temperature: -40℃~+70℃ (conventional), optional: -40℃~+400℃, -40℃~+800℃ (up to 1300℃)


Relative humidity: ≤10-95%RH (conventional) non-condensing occasions, optional: 10-99%RH for high temperature and high humidity occasions, when ordering


(Need to indicate, need to be equipped with pretreatment system)


Working voltage: 12~30V (DC DC, the standard power supply of a single device is 24V, 1A or DC switching power supply greater than 1A)


Power reference: 24V, 2.1A switching power supply can drive 40 toxic gas detectors, or 15 combustible and infrared gas detectors


Explosion-proof form: flameproof type ExdⅡCT6


Connecting cable: 4~20mA select three-core shielded cable, RS485 select four-core, single wire diameter ≥1.5mm when the distance exceeds 1000 meters; the shielding layer is connected to the ground


Protection level: IP66 waterproof and short-term rain, long-term rain needs to be equipped with a rain cover or choose a shell without display or specify when ordering


Dimensions: 210×170×85mm


Weight: 1.8Kg


Optional accessories: wall mounting bracket, mounting bracket fixed on the pipeline (four points, six points), pipe installation stainless steel threaded welding seat (the pipe size needs to be indicated, such as DN50, DN15...), normal temperature and high humidity pretreatment System, high temperature and high humidity pretreatment system, high temperature, high humidity and high dust pretreatment system, pressure reducing valve, flow meter, temperature and humidity measurement, large capacity SD memory card, rain cover, 24VDC or 220AC sampling pump (sampling distance 10 meters) , Vacuum pump (sampling distance greater than 40 meters), 24V switching power supply.


Accessories needed for computer monitoring: free PC software, RS485/RS232 converter, notebook computers without RS232 interface also need USB/RS232 conversion cable, if you want network transmission, you also need a TCP/IP converter


Application occasions: petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment and other occasions that require fixed installation and online gas concentration detection

Application

Sorry  There is no "Application", you can view other services。