MIC-600 Fixed Poisonous and Harmful Gas Alarm

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
The MIC-600 fixed ozone detector is used for 24-hour continuous online monitoring of gas concentration and temperature and humidity measurement on-site, on-site display of concentration and over-standard sound and light alarm, remote data transmission. A 2.5-inch high-definition color screen is used to display the concentration in real time, and imported brand sensors (Honeywell, Japan Nemoto, British CITY, British Alpha, British Dynament, Swiss Membrapor, etc.) are selected according to different detection gases. ......
Product Details

Details

Features of MIC-600 fixed toxic and harmful gas alarm:


●Intrinsically safe circuit design, explosion-proof certification, secondary lightning protection, anti-static, lightning protection and anti-static capabilities exceeding national standards, resistance to high-intensity pulse surge current impact. High reliability and stability. Anti-reverse design, any form of reverse connection will not damage the instrument
●It complies with EMI and EMC standards, and has passed national standard testing and CMC measurement instrument license certification.
●Standard bus RS485 (RTU) and 4-20mA standard signal output at the same time, 3 groups of relay switch output, on-site sound and light alarm (optional). Optional frequency output 200-1000Hz, Hart protocol signal, 1~5V output, wireless transmission (2~5km or unlimited distance). Wired or wireless remote real-time monitoring can be performed. Data can be uploaded to a phone or transmitted to the Environmental Protection Agency, other monitoring centers, monitoring equipment, and monitoring computers via a local area network or the Internet. The concentration of the site can be monitored in real time through free upper computer software or gas alarm controllers.
●Compatible with various secondary meters, data acquisition modules, PLC, DCS systems, can directly drive solenoid valves, fans, alarms and other equipment, and can also drive high-power equipment by driving intermediate relays. Optional MIC2000 controller can monitor 1000 detectors at the same time.
●Large-capacity data storage function, can record real-time concentration value, temperature and humidity, or only alarm value and time. Support local storage or SD card storage, please specify when ordering larger capacity. SD card storage capacity can be customized. Data export and analysis are carried out through the free upper computer software, and data can be viewed or deleted on the machine. It can be set to automatically overwrite data or not to overwrite data when the capacity is insufficient, and automatically stop recording.
●The standard infrared remote control can realize the operation without opening the cover in dangerous situations, such as: modify the alarm point, concentration calibration, zero point calibration, silence, restore the factory, enter the menu, view the record, 4mA output, 20mA output (calibrate other acquisition equipment) This function is required).
●Chinese and English interface can be selected, the default Chinese interface, support free switching of gas concentration units, conventional gas does not need to enter the molecular weight, and the molecular weight of special gas is automatically calculated and switched after entering the molecular weight. The units are optional: PPM, mg/m3, Vol%, LEL% , PPHM, ppb, mg/L
●The 2.5-inch high-definition color screen (LCM) displays real-time concentration, time, temperature, humidity, storage status and other information, and can simultaneously detect 1 to 6 gas concentrations and temperature and humidity. The menu interface uses high-definition simulation icons to display the function names of each menu , Concise Chinese or English operation prompts.
●Three display modes can be switched: simultaneous display of multiple gas concentrations, large font cycle display of single channel gas concentration, real-time curve, automatic or manual cycle between channels can be switched, you can set whether to display the maximum value, minimum value, gas name , You can view the historical record graph.
●Automatically track the zero point to prevent drift, temperature compensation, multi-level calibration, which can simultaneously meet the national standard and the standards of the local and provincial metrology bureaus in various regions
●Data recovery function, automatic identification and prevention of incorrect operation of concentration calibration, which can avoid defects caused by improper operation.
●Can record calibration log, maintenance log, troubleshooting countermeasures, reminder of the expiration of sensor life, reminder of the next concentration calibration time

Parameter

Technical parameters of MIC-600 fixed toxic and harmful gas alarm:


Detection gas: toxic gas, oxygen, carbon dioxide, flammable and explosive gas, TVOC and other gases can be combined at will.
Optional: It can detect any 1 to 6 kinds of gases and temperature and humidity at the same time.
Application occasions: petroleum, chemical, pharmaceutical, environmental protection, gas distribution, storage, flue gas analysis, air treatment and other occasions that require fixed installation and online gas concentration detection.
Detection range: 0~1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 99% LEL, 20%, 50%, 99.999%, 99%Vol optional, other ranges can be customized.
Resolution: 0.01ppm or 0.001ppm (0~10 ppm); 0.01ppm (0~100 ppm), 0.1ppm (0~1000 ppm), 1ppm (over 0~1000 ppm), 0.01 mg/liter (0~200 % Mg/L), 0.1% LEL, 0.01%, 0.001% Vol.
Detection principle: electrochemistry, catalytic combustion, infrared, thermal conductivity, PID photoion, etc., depending on the gas type, range, site environment and user needs.
Allowable error: ≤±2%F.S (other or higher accuracy can be customized)
Linearity: ≤±1%
Response time: T90≤30 seconds Repeatability: ≤±1% Uncertainty: ≤±1%
Signal output: bus system RS485 (RTU), three (four) wire system 4~20mA, optional: 0~20mA, 1~5V, 0~5V, 0~10V, wireless transmission, network transmission, SMS alarm. Recovery time: ≤30 seconds
Working environment: temperature: -40℃~+70℃, humidity: ≤10~95%RH (conventional) non-condensing occasions, use in condensing occasions must be customized or specify the use environment when ordering. Working pressure range: atmospheric pressure ± 30%, some sensors can detect under 7 kg pressure
Display mode: on-site 2.5-inch high-definition color screen display, optional on-site no display, or optional MIC2000 controller for remote display, control, and alarm
Working voltage: 12~36VDC DC, the standard power supply of a single device is 24V, 1A or more than 1A DC regulated switching power supply
Power consumption: instantaneous maximum current: 60 mA for electrochemical principle, 120 mA for catalytic or infrared principle
Power reference: 24V, 2.1A switching power supply can drive 30 toxic gas detectors, or 15 combustible and infrared gas detectors
Working mode: online installation, online detection, diffusion measurement; pipeline, flow, and pump-suction measurement are optional.
Installation method: pipeline type, wall-mounted type. The working pressure of the pipeline type is ±30% of atmospheric pressure.
Alarm mode: default 1 channel, optional 3 passive contact (dry node) output, three-level alarm, alarm point can be set. On-site sound and light alarm (optional).
Connecting cable: 4~20mA select three-core shielded cable, RS485 select four-core, when the distance exceeds 1000 meters
The diameter of a single wire is ≥1.5mm; both ends of the shielding layer are connected to the ground and ensure a good grounding.
Protection level: IP66 waterproof splash and short-term rain
Explosion-proof type: flameproof type
Explosion-proof mark: Exd IIC T6 Gb Explosion-proof certificate number: CNEx17.3959
Executive standard: GB15322.1-2019 "Combustible Gas Detector Part 1"
GB 3836.1—2010 "General Requirements for Electrical Equipment for Explosive Gas Atmospheres"
GB 3836.2—2010 "Electrical Equipment for Explosive Gas Environment Explosion-proof Type "d""
Dimensions: 260×180×90mm (L×H×W) atmospheric chamber
260×230×90mm(L×H×W) atmospheric chamber with light
240×180×90mm (L×H×W) conventional air chamber
240×230×90mm (L×H×W) conventional with light (different depending on the combination)
Weight: 1.8Kg (different depending on the combination)
Standard accessories: manual, certificate, warranty card, outer box packaging
Optional accessories: integrated sound and light alarm, split sound and light alarm, 24V DC power supply, RS485/RS232 converter, USB/RS232 conversion cable, TCP/IP converter,
Wireless transmission (optional): optional function, can wirelessly transmit data to phones, remote monitoring centers, monitoring computers and other monitoring equipment, use the upper computer to perform data analysis, storage, printing and other functions on the computer
Pretreatment system (optional): Optional: normal temperature and high humidity pretreatment system, high temperature and high humidity pretreatment system, high temperature, high humidity and high dust pretreatment system
Temperature and humidity measurement (optional): optional: temperature -40℃~+120℃, accuracy 0.3℃, humidity: 0-99%RH, accuracy 3%RH
Mounting accessories: optional: wall mounting bracket, mounting buckle fixed on the pipeline (four points, six points), pipe installation stainless steel threaded welding seat or flange (need to indicate the pipe or flange size, such as DN50, DN15 ...), rain cover, 24VDC or 220AC sampling pump (sampling distance 10 meters), vacuum pump (sampling distance 40 meters), 24V switching power supply, pressure reducing valve, flow meter.