Portable Emissions Measurement System 23nm - 2500nm Gasboard-9805

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
Gasboard-9805 is a portable emission measurement system developed based on Cubic Ruiyi self-developed core gas analysis technology, measures the concentration of CO, CO2, NO, and NO2 in exhaust gases, and particulate matter, emission flow, GPS data, ambient temperature and humidity, pressure measurement, as well as automatic calculation of total emissions.The system is modular design with built-in battery(more than 4 hours battery lifetime). Infrared NDIR technology for CO and CO2 concentration measurement and ult......
Product Details

Details

  • · Self-developed core gas analysis technology. Infrared NDIR technology measures CO and CO2;UV-DOAS technology simultaneously measures NO and NO2 with high accuracy, no need for NOx converter and free maintenance.
    · Simple operation and usage. Easy operation;support test process guidance;test result storage and report generation functions.
    · Modular design, flexible to use. Both of the GAS and PN modules can be used separately to meet different measurement request.
    · Strong endurance, meets on-vehicle test requirements. More than 4 hours battery lifetime of the built-in battery. No external battery needed. Supports a complete actual driving pollutant emission test.
    · Excellent performance; Meets national standard requirements. Comply with the "Limits and Measurement Methods of Pollutant Emissions from Diesel Engines for Non-Road Machinery (China Phase 3 and 4)" (GB 20891-2014) and "Technical Requirements for Control of Pollutant Emissions from Non-Road Diesel Machinery" (HJ1014-2020) standard requirements.
    · Great environmental adaptability. Great environmental adaptability, not affected by vehicle vibration, heavy pressure, ambient temperature and humidity change.

Parameter

Performance parameter
GasMeasurement range CO:0~10%
Analysis CO2:0~20%
Device NO:0~3000ppm
NO2:0~1000ppm
Resolution CO,CO2:0.01%
NO,NO2:1ppm
Precision ≤1%F.S.
Accuracy <±2% of reading or ±0.3% F.S., whichever is greater
Sensor response time T10-90 <2.5s
System response time T0-90 ≤10s
Zero drift (4 hours) CO:≤±50ppm
CO2:≤±0.10%
NO,NO2:≤5ppm
Span drift (4 hours) CO: ≤2% of reading or ≤±50ppm, whichever is greater
CO2: ≤2% of reading or ±0.1%, whichever is greater
NO, NO2: ≤2% reading or ≤5ppm, whichever is greater
PN Measurement Module Measurement range 600 ~ 1.3 * 10 ^ 9 # / cm3
Particle size range 23nm~2500nm
Rise time T10-90 ≤3s
Discharge Flow Meter Range 10~600kg/h; 100~2000kg/h;200~4000kg/h
Discharge temperature -5~500℃
Accuracy <(±2% reading)or(±0.5%F.S.)
or (±1.0% of the maximum flow rate of the calibrated EFM) whichever is greater
Precision <1%F.S.
Linearity |Xmin*a1-1+a0|≤3%max, slope a1:0.97~1.03,
Standard deviation SEE≤2%max,
determination coefficient r2≥0.990
Rise time T10-90 <1s
Response time <3s
Performance parameter
Working environment temperature (-10~45)℃
Power supply 24V, maximum power consumption 240W
Connection signal
Communication RS485,WIFI,RJ-45 Ethernet

Application

Petroleum and chemicals, natural gas, gases for industrial purposes, semiconductor industry, drying industry, food industry, electric power industry, mechanical manufacturing, air separation industry, and pharmaceutical industry.