Welcome Customer !

Membership

Beijing Zetron Technology Co., Ltd
Free Member ·1YRS
,
Other

Main Products: 气体检测仪

Xwboo>Products
Product Categories

Beijing Zetron Technology Co., LtdFree·1YRS

  • E-mail

    info@bjzetron.com

  • Phone

  • Address

Contact Now

CH4 LNG LPG Digital Laser Methane Detector

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
The RMLD is the first of a new generation of leak survey instruments that will greatly improve the productivity and safety of leak survey.
Product Details

Details

The HEATH Remote Methane Leak Detector (RMLD) is a highly advanced technology, capable of detecting methane leaks from a remote distance.


The RMLD is the first of a new generation of leak survey instruments that will greatly improve the productivity and safety of leak survey.

 

With the RMLD it is now possible to survey areas that are hard to reach or not easily accessible. The RMLD does not have to be within the gas plume because it uses laser technology known as Tunable Diode Laser Absorption Spectroscopy.


As the laser passes through a gas plume, the methane absorbs a portion of the light, which the RMLD then detects. This technology makes it possible to detect leaks along the sight line without always having to walk the full length of the service line.

 

Parameter

Detection MethodTunable Diode Laser Absorption Spectroscopy (TDLAS)
Measurement Range0 to 99,999 ppm-m
Sensitivity5 ppm-m at distance from 0 to 50 ft (15 m)
10 ppm-m or better from 50 to 100 ft (15 to 30 m)
Detection Distance100 ft (30 m) nominal. Actual distance may vary due to background type and conditions
Beam SizeConical in shape with a 22" width at 100 ft. (56 cm at 30 m)
Detection Alarms ModesDigital Methane Detection (DMD):
Audible tone relative to concentration when detection threshold exceeded.
Adjustable Alarm Detection Threshold from 0 to 255 ppm-m
Pure Tone:Continuous audio tone relative to concentration
System Fault WarningAudible tone and indication on the display
Self Test & CalibrationBuilt-in Self-Test and Calibration function verifies operation and adjusts laser
wavelength for maximum sensitivity. Test gas cell integrated
with carrying case.
ComplianceEMC (EN61000-6-2, EN6100-6-4) Pending
Laser Eye SafetyIR Detector Laser: Class I
(CDRH, ANSI and IEC)Green Spotter Laser: Class IIIa
Do not stare into beam or view directly with optical instruments.
DisplayLarge easy to read backlit LCD (.75" Numeric)
Operating Temperature0° to 122° F (-17° to 50° C)
Humidity5 to 95 % RH, non-condensing
EnclosureIP54 (Water splash and Dust resistant)
Instrument Weight9 lbs (Transceiver 3 lbs, Controller 6 lbs) (4 kg; 1.3 kg, 2.7 kg)
Carry Case14lbs;34"x91⁄2"x14" (6.4kg;86cmx24cmx36cm)
Power SupplyInternal rechargeable Li-ion battery
External Backup Battery pack with 5 C cells (Optional)
Battery Operating Life8 hours at 32° F without backlight on (Internal battery)
Battery ChargerExternal, in-line, 110 – 240 VAC, 50 / 60 hertz universal type with charge indicator (8 hours maximum to full charge)
Shoulder StrapSingle over the shoulder padded strap Ergonomic dual strap and belt system (Optional)

Application

This fast-acting technology is ideal for difficult-to-protect applications such as:

  • production areas
  • tank farms and product storage
  • loading and unloading facilities
  • hazard waste treatment and storage
  • processes with high temperatures, pressure and flammable fuels
  • pump rows
  • manifolds
  • hot oil systems
  • rail car loading racks
  • hydrocarbon filling and storage areas
  • chemical storage tanks
  • aircraft hangars