Welcome Customer !

Membership

Shandong BOS Energy Technology Co., Ltd
Free Member ·1YRS
,
Other

Main Products: 冷水机

Xwboo>Products

Shandong BOS Energy Technology Co., LtdFree·1YRS

  • E-mail

    linzhaoyan@bos-power.com

  • Phone

    0086-531-88662200

  • Address

    Jinan City, Shandong Province, Ming Shui Econ

Contact Now

Frequency converter

Model
Nature of the Manufacturer
Other
Product Category
Industrial power supply
Place of Origin
City, Province
Overview
AC60 series power supply is the one that change theelectric supply into the required voltage and frequency through powerconverting circuit.Its main characteristic is to supply pure and stable sinewave power output,low harmonic distortion,high-stability frequency andregulation.It can impersonate many of the world of frequency voltage and outputcharacteristics,and cover the whole industry needs,entirely consistent with thedesign engineer in research and production and testing of the product testingand life, an......
Product Details

 1. High reliability

The main components are imported components, originalMitsubishi IGBT inverter module, drive protection for the original Mitsubishimovement, a perfect drive protection circuit to ensure reliable IGBT work.

2. Dynamic response speed (patented technology)

The use of double closed-loop feedback circuit, the innercurrent loop to ensure that the nonlinear load waveform distortion; outer ringvoltage ring to ensure sudden increase in load pressure drop <1%, thereaction rate is less than 2mS, the control circuit for analog circuits,anti-interference ability, , Some manufacturers use the digital controlsampling required by the A / D conversion, calculation, D / A conversion,control process is long, slow response, poor anti-jamming capability and easyto crash.

3. Three-phase power supply can adapt to any unbalancedload

Three-phase power supply can be three-phase system, butalso single-phase sub-tune. Three-phase power supply main circuit and controlcircuit in accordance with the three sets of independent single-phase powersupply design. The main circuit is composed of a rectifier, a DC filter, aninverter, an AC filter and a transformer. Three sets of single-phase invertercircuit output mutual difference 120 angle, independent of each other in thetransformer primary side, connected to the transformer secondary star, theoutput of the required three-phase AC. Voltage and waveform control Forsingle-phase output, three independent single-phase controllers are used sothat any phase of a three-phase power supply can be used as a single-phasepower supply independently and can accommodate any unbalanced load, resultingin a significant increase The power of the load adaptability. Really do a loadimbalance.

4. Man-machine interface is good, table source one, highaccuracy

Voltage, frequency, current, power / power factor fourwindow measurement display, accuracy of 0.5, the source table integration.

5. Great load capacity

Power components of reasonable application, can withstand3 times the rated current, and will not cause pressure drop.

6. Excellent stability

Frequency stability ≤ 0.01%, load stability ≤ 1%, theoutput frequency of oscillation generated by the quartz oscillator, it is verystable and accurate.

 

Model

11005

11010

11030

11050

11100

31150

31200

313000

31450

311000

Capacity(VA)

500

1K

3K

5K

10K

15K

20K

30K

45K

100K

Output limit currency

LOW(A)

4.2

8.4

24

42

84

126

168

250

375

840

HIGH(A)

2.1

4.2

12

21

42

63

84

125

188

420

Circuit model

IGBT/SPWM pulse width adjustment mode

Output frequency

50Hz/60Hz  45-65Hz

Load stability

≤±1%

frequency stability

fixed-frequency≤±0.01%,frequency modulation≤±0.1%

Input voltage

220V±10%

380V±10%

Phase

single phase

three phase four wire

Wave distortion

≤3%

Output voltage

low-grade:0-150V continuous-tuning; high-grade:0 - 300 V continuous-tuning

Reaction time

≤2mS

DPI ( dots

per inch )

frequency meter

0.1Hz

Voltage meter

0.1V

Current meter

0. 1A

Power meter

0.1W

Ammeter display

Frequency, voltage, current, power or PF 4 number display

Protection function

over voltage, over current, over temperature, over load, short circuit, and automatic alarm

Insulation reactance

500Vdc 20MΩ

Pressure endurance insulation

1500Vac/5mA/1min

Cooling model

Compulsive fan cooling

Working temperature

-10℃-45℃

Relative humidity

0-90%(No condensing)

Altitude

1500meters

Dimension (W×L×H)mm

410*440*135

460*440*220

560*350*600

660*400*700

830*450*1100

1160*520*1370




































Model

13060

13100

33150

33300

331000

332000

333000

334500

336000

338000

Capacity(KVA)

6

10

15

30

100

200

300

450

600

800

Output limit currency

LOW(A)

16.8

27.6

41.6

84

276

none

HIGH(A)

8.4

13.8

20.8

42

138

260

400

600

800

1050

Pulse


&l