Pulse Test Bed for Large Heat Exchanger (Walk-in Type)
Pulse Test Bed for Large Heat Exchanger (Walk-in Type)
The test bed for large heat exchanger is designed for pulse fatigue test of micro-channel heat exchanger, condenser and evaporator of household/commercial air conditioning with large specification of size over 1000mm. The whole machine adopts walk-in structure to form the completed and sealed test space.
1.Technical parameters
1)Test pressure: 0~8MPa;
2)Pulse frequency:0.5~5Hz;
3)Test medium: Hydraulic Oil, PAG oil;
4)Environment temperature: -50 ~ 150 ℃ at will;
5)Medium temperature: RT ~150℃ at will;
6)Internal size of the chamber: 3500(D)×2500(W)×2200(H)mm;
7)Hose number of single test: 2~8 pieces;
8)Pressure waveform: sine wave, square wave, triangular wave and T-wave.
2. Function and characteristics
1)The test chamber is set with integrated door opener with urgent opening device set inside. The chamber door can be opened from both the outside and inside;
2)Provided with access control and monitoring system;
3)Automatic control of the servo control system, pulse pressure, test times and pulse waveform can be set through computer;
4)Major cycles begin to discharge automatically before the test;
5)The number of test cycles is set at will and it stops automatically after the test is completed;
6)Workpiece failure alarm, over-temperature alarm, low liquid level alarm, fault information prompt function;
7)The Chinese-English operating interface adopts high speed data acquisition technology to provide data analysis ability to meet the requirement of test analysis and special test data processing;
8)Data acquisition software of U.S. NI Company is used for real-time analysis and storage and the test report may be produced and printed. Data share through LAN and other computers is allowed.