YCL iron housing capacitor start and run motor is optimized from YC single phase capacitor start motor. The mounting dimension is fully conformed with IEC standard. YCL single phase asynchronous motor is superior motors delivering excellent torque enabling the toughest jobs to be handled with dependable ease and perform well in high voltage fluctuating regions. YCL monophase asynchronous motor has the features of quiet operation, corrosion resistant, low vibration, low power consumption, long lifespan, low start current and good operation in hot environment. YCL motor is used in the pumping, compressor, agriculture, farming, building service and manufacturing industry.
Product Detail
Motor Type: single phase asynchronous motor for air conditioner
Output Power: 0.75 kW - 5.5 kW
Frame Size: IEC 90 - 132
Number of Poles: 2 / 4
Voltage: can be customized based on users
Frequency: 50 & 60 Hz
Protection Level: IP54 / IP55
Insulation Class: B / F
Cooling Method: IC411
Duty: S1 (continuous)
Use Conditions: Ambient temperature -15℃-40℃, altitude ≤1000 meters.
Product Parameter (specification)
Single phase machine and single phase ac machine and single phase induction machine
Production Features
Know More Us
Why Us
Service and Packing
FAQ
How to disassemble the motor?
When inspecting and repairing the motor, it is often necessary to disassemble the motor and then assemble it. Improper disassembly will damage the motor. Therefore, the motor maintenance personnel must master the technology of correctly disassembling and assembling the motor.
The following 7 steps should be followed when disassembling the special motor for the :
①Remove all external wiring and mark each terminal, especially the terminal with polarity (DC motor).
②Remove the screws of the commutator side end cover and bearing cover, and open the end cover.
③Before disassembling the commutator side end cover, mark the joint between the end cover and the base, and then padded a wooden board, hit the edge of the end cover evenly with a hammer, so that the end cap stop is slowly separated from the base and Bearing outer ring.
④Wrap the commutator with thick paper or cloth to keep the commutator clean and avoid bruising.
⑤Remove the end cover screw on the shaft extension side, and pull out the armature and end cover from the stator core. Take care not to damage the armature winding during operation.
⑥ To replace the bearing, remove the bearing screw on the shaft extension side, and remove the bearing cover, end cover and bearing.
⑦All the disassembled parts should be placed and stored in the order of disassembly, so as not to be lost, and to facilitate the assembly process.
When assembling the motor, the operation steps are opposite to the above disassembly steps, just reset the parts and wiring according to the marks.