Cable Fault Locating Equipment

Model
Nature of the Manufacturer
Manufacturer
Product Category
Power Cable Testing Equipment
Place of Origin
City, Province
Overview
Sampling frequency: 100MHzPulse width: 0.1uS/2uSThe minimum resolution is 0.5mTest blind area: ≤20mRanging range: ≤30kmMeasurement error: ≤±(0.5%×L+1m), L is the cable lengthPower supply mode: built-in rechargeable lithium battery power supply; Charging 220VAC±10%, 50Hz/60HzWorking conditions: -20~+60℃, relative humidity≤90%Path meter: output signal: 15kHz intermittent, output power: 100WHigh voltage pulse: impact high voltage: 0~35kV optional, discharge power: 1225J
Product Details

The XHHV535-2TS cable fault locating equipment integrates TDR cable fault tester, cable path meter transmitter module, high voltage pulse generator, rechargeable battery pack and cable fault pinpoint locator. It is used to detect the main insulation fault of power cables with voltage levels of 35kV and below; to calibrate the cable length; to accurately detect the cable burial direction and depth.

 

★Cable fault tester, simple operation software interface, single-chip centralized control, touch operation mode, built-in large-capacity lithium-ion battery, stable and reliable, easy to use. Independent power supply and power supply system are used to prevent power supply interference during shock discharge. For details, see the cable fault tester section.

 

★The cable path meter is powered by an internal battery pack, which is easy to use and includes functions such as overload protection and amplitude adjustment. See the Cable Router section for details.

 

★The high-voltage pulse generator is powered by an internal battery pack or 220VAC, including DC withstand voltage, single pulse, and periodic pulse output functions, including a signal feedback device to facilitate sampling by the cable instrument host; including zero-position protection, automatic shutdown and other functions. See the High Voltage Pulse Generator section for details.

 

★Rechargeable battery pack: 12.6V battery pack, which provides power for the high-voltage pulse generator and cable routing instrument.

 

★Cable fault pinpoint locator: It adopts the principle of acoustic-magnetic synchronization, and is used to accurately locate the fault point directly above the faulty cable within the scope of rough fault measurement.

 

The XHHV535-2TS cable fault locating equipment is suitable for low-resistance, short-circuit, open-circuit and disconnection faults of power cables, high-frequency coaxial cables, street light cables, and buried wires of various materials with different cross-sections and different media, as well as high-resistance leakage and high-resistance flashing network failure.



The structure is shown below

_20220908114023_


1. TDR Cable fault tester

2. Cable fault path meter

3. Rechargeable battery pack

4. High voltage pulse generator

5.Cable fault pinpoint locator



Technical Parameters         

1. TDR cable fault tester

• Sampling frequency: 100MHz;

• Pulse width: 0.1uS/2uS;

• Minimum resolution 0.5m;

• Test blind zone: ≤20m;

• Ranging range: ≤30km;

• Measurement error: ≤±(0.5%×L+1m), L is the cable length;

• Power supply mode: charging 220VAC±10%, 50Hz/60Hz; built-in 5200mAH lithium battery power supply;

• Working conditions: -20~+60℃, relative humidity≤90%;

 

2. Cable path meter

●Transmitter:

Output signal: 15kHz intermittent

Output power: 100W

Output current: 0~2A

Working power supply: built-in 100AH power supply;

●Receiver (cable fault locator):

Magnification, 500,000 times

Detection accuracy: ±0.2m

Output impedance: 350Ω

Working power supply: two standard 9V batteries; quiescent current: <10mA

 

3. Rechargeable lithium battery pack

The portable cable fault location system is a internal power supply instrument.

●The battery switch needs to be turned on when using, and the battery indicator light is on.

●When charging the instrument, turn on the battery switch, and then connect the charger. The charging socket is on the side panel.

●Please refer to the instruction manual of the charger for the usage method of the charger.

●The battery switch is responsible for supplying power to the high-voltage pulse generator and the cable routing instrument. Power and charging controls for the cable fault tester are not provided.

●Please charge when the low voltage indicator of the battery pack is 2 bars. Otherwise, when the high-voltage pulse generator is impacted and discharged, there may be a phenomenon that the high-voltage pulse generator cannot be brought to work by the impact-discharge due to lack of power.

 

4. High voltage surge generator

●Impulse high voltage: 0~35kV optional

●High voltage divider: voltage accuracy level 1.5

●Built-in capacitor: 2μF

●Output voltage polarity: negative polarity

●Discharge power: 1225J

●Impact time: about 5 seconds for automatic impact, arbitrary control time for manual impact

●Impact power: 2000W

●Volume: 534L×444W×805H

●Weight: no more than 130kg

●Working power supply: AC 220V±10% 50Hz±2Hz, built-in 100AH power supply

●Ambient temperature: -20~+50℃

 

5.    Cable fault pinpoint locator

●Detection: vibration waves, sound waves, magnetic waves

●Magnification: 500,000 times

●Output impedance: 350Ω

●Detection depth: more than 10 meters

●Positioning accuracy: ±0.2m

●Working power: two standard 9V batteries

●Quiescent current: <10mA, continuous work more than 20 hours



Operation interface introduction

_20220908114429


 

1 Display: 7-inch industrial-grade touch display;

2 Signal: low-voltage pulse method pulse signal sampling interface, high-voltage flashover method sampler receiving signal sampling interface;

3 Battery indicator (Battery): Indicates the internal battery power, displayed in 4 grids;

4 switch (ON/OFF): turn on/off the working power;

5 Displacement: Adjust the displacement knob when acquiring waveforms to change the baseline height of the acquired waveforms;

6 Amplitude: Adjust the amplitude knob when acquiring waveforms to change the amplitude of the acquired waveforms;

7 Charge: DC12V charging port, connect the 12V/1A charger to start charging.


_20220908114449

1. Output meter head: When the pointer of the meter head swings, it means that there is an output signal; when the pointer does not move, it means that there is no output signal; , does not represent the specific unit value);

2. Overloading indicator (Overloading): overload indicator light, when the output is short-circuited or the signal is too large, the light is on;

3. Power switch (ON/OFF): "I gear" turns on the system power, and "0 gear" turns off the system power;

4. Output Adjust (Out Adjust): output amplitude adjustment knob, change the size of the output amplitude;

5. Reset button (Reset): When the overload light is on, after reducing the output amplitude, press this button to restart the signal generator to make the path signal output again;

6. Battery Switch: (Battery Switch): This switch needs to be turned on first when using, and this switch needs to be turned on when charging the instrument;

7. Battery: Indicates the battery level in real time when the built-in battery is working;

 

Introduction to the side panel of the Path meter

_20220908114458

1. Path output positive (Path OUT): the signal source output is positive, connected to the phase line of the cable;

2. Path output negative (Path OUT): signal source output negative, connect to the ground wire of the wire;

3. Charge: DC12.6V charging port, connect 12.6V20A charger to start charging;

6.2.3 Cable Path Receiver (Cable Fault Locator)

Receive the pulse signal sent by the cable routing instrument, so as to accurately detect the buried depth and direction of the cable. (For details, please refer to the manual of the pointing device)


_20220908114506

1. The battery switch needs to be turned on when using, and the battery indicator light is on.

2. When charging the instrument, turn on the battery switch, and then connect the charger. The charging socket is on the side panel.

3. Please refer to the instruction manual of the charger for the usage method of the charger.

4. The battery switch is responsible for supplying power to the high-voltage pulse generator and the cable routing instrument. Power and charging controls for the cable fault tester are not provided.

5. Please charge when the low voltage indicator of the battery pack is 2 bars. Otherwise, when the high-voltage pulse generator is impacted and discharged, there may be a phenomenon that the high-voltage pulse generator cannot be brought to work by the impact-discharge due to lack of power.


_20220908114514


1. Voltmeter: high voltage output voltage indicating kV meter.

2. Power light (Power): After turning on the power switch, the indicator light is on.

3. High voltage lamp (HV): On means there is high voltage output, and off means there is no high voltage output.

4. Single Discharge: When the mode selection key is in the Single function, this key is valid.

5. Mode select: divided into three modes: withstand voltage (DC), single (Single), and cycle (Cycle). DC is the withstand voltage function. When this function is selected, the cable is subjected to withstand voltage test at this time; Single is a manual function. When this function is selected, the high voltage will be boosted after the high voltage is activated. Press the Single button to manually trigger the shock discharge; Cycle is an automatic function. When this function is selected, the high voltage is activated at this time to boost the voltage, and the instrument will automatically trigger the shock discharge for about 5 seconds.

6. Start button (Start): in the zero position, press the start button, at this time the high voltage starts and the high voltage light is on. In the non-zero state, the start high pressure light does not light up.

7. Stop button (Stop): When the test is completed or there is an abnormality, press this button to cut off the high voltage output, and the remaining high voltage will also be automatically discharged at this time.

8. Switch: "I" gear, use AC220V power supply to supply power to the system;

               "II" gear, use the internal battery to power the system, and turn on the battery switch when using;

               "O" gear, shutdown;

9. Fuse socket: the place where the AC220V power supply system fuse is installed;

10. Power socket (AC220V): working power supply of the instrument, AC220V connection port;

11. Voltage control knob: When this knob is in the zero position, the zero position light is on, and the high voltage can be activated. After the high pressure is started, the pressure can be boosted through the pressure regulating knob.

12. Zero position light (Zero): Indicates that the pressure regulating knob is in the zero position state, and the start button is only valid when it is on.

13. Signal: Use double Q lines to connect the machine and the cable fault tester to collect waveforms for flashover, which is only valid for high-voltage flashover.

14. Ammeter: Indication of the current on the low-voltage side.

 

Introduction to the side panel of the high voltage surge generator

_20220908114523

1. High voltage output (HV OUT): dedicated DC high voltage output terminal.

2. Path output positive (Path OUT): the signal source output is positive, connected to the phase line of the cable, and connected when using the path function;

3. Path output negative (Path OUT): signal source output negative, connect to the ground wire of the wire, connect when using the path function;

4. Charge: DC12.6V charging port, connect 12.6V20A charger to start charging;

5. High voltage ground (HV GND): Also known as the high voltage tail, it must be grounded reliably to prevent high voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.

6. Safety GND: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified or electric shock to personnel.

7. Sampling GND: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled in the high-voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).



Packing list

                                              Instrument composition list and diagram

Name

Qty.

Photo

Name

Qty.

Photo

Host

1

image

Power cable

1

image

HV output cable

1

image

Ground wire

1

image

Double Q line

1

image

Sampler

1

image

Discharge rod

1

image

Fuse(8A)

3

image

Receiver

1

image

Output line(black)

1

image

Output line(red)

1

image

Probe

1

image

Headphone

1

image

Charger

1

image

Strap

1

image

Stylus

1

image

Single Q line

1

image

Charger

1

image



Welcome you contact us for more information.


Remarks

◆This cable fault locating equipment has passed the international standard certification ISO9001

 

◆The general delivery time of the cable fault locating equipment is 8-15 working days. The specific negotiation at the time of ordering shall prevail.

 

◆The standard packaging is a wooden box for export to protect the safety of equipment transportation.

 

◆Usually shipped by international express, such as FEDEX, DHL, , ARAMEX, etc. Shipping method can be negotiated.


_20220806155356__

 downLoadImg (3)_


FAQ


Q:  What’s your payment terms?

A:  Payment≤USD2000, 99% paid in advance. Amount over USD2000, can be negotiated.

Q: Are you a manufacturer?

A:  Yes, We are manufacturer.

Q:  Why should you buy thecable fault location system from us?

A:  Professional R&D and technical support, accept OEM, ODM orders;

Strict quality control and one year of warranty.

Short lead time and fast delivery.

Quick response to your any inquiries.