Welcome Customer !

Membership

XZH TEST
Free Member ·1YRS
XiAn,ShanXi
Manufacturer

Main Products: Transformer Testing Machine|Other Testing Machines

Xwboo>Products

XZH TESTFree·1YRS

  • E-mail

    happyxzh@xzhjdkj.com

  • Phone

    86-029-86093121

  • Address

    Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an City, Shaanxi Province, China

Contact Now

ARC Cable Fault Pre Locator

Model
Nature of the Manufacturer
Manufacturer
Product Category
Power Cable Testing Equipment
Place of Origin
City, Province
Overview
ARC Cable Fault Pre LocatorSampling frequency: 400MHz;Minimum resolution:0.5m(100m/us)Low voltage pulse width:0.2uSTest blind spot:≤20mRanging range: ≤60kmMeasurement error:≤±(0.5%×L+1m),L is the cable lengthWorking conditions: temperature -25℃~+65℃, relative humidity 85%, atmospheric pressure 750±30mmHg
Product Details

XHGG502 ARC Cable Fault Pre locator is a special instrument for measuring and analyzing power cable status and fault distance. It combines modern electronic technology and computer technology to realize signal filtering, acquisition, data processing, graphic display and graphic analysis to complete cable speed measurement, cable Length test, cable fault distance test.

 

This cable fault locator adopts 12.1-inch industrial-grade computer control, windows operating system, touch operation mode, ultra-high brightness, large LCD screen display interface for user-friendly use, automatic continuous sampling, and real-time accurate waveform acquisition.

 

XHGG502 ARC cable fault pre locator adopts the latest technology "eight-pulse method" (multi-pulse method) detection technology. It presents the simplest short-circuit fault waveform for any high-impedance fault, similar to low-voltage pulse characteristics, and is easy to read.

 

It also has the operation modes of shock high voltage flashover method and low voltage pulse method, which is convenient to detect various cable faults. The success rate of fault detection, test accuracy and test convenience are better than any domestic testing equipment.

20220811161217daa641e4992f600d3d17f64b

The test working modes of ARC cable fault pre locator include low voltage pulse method, high voltage flashover method, and multiple pulse method. Here focus on the multiple pulse method that is different from other devices.

 

The purpose of using the multiple pulse method to test the cable fault is to make the sent low-voltage test pulse effectively avoid the cosine large oscillation interference that occurs at the moment of the high-voltage impact of the faulty cable, and obtain a standard and clear similar short-circuit during the relatively stable short-circuit arc at the fault point. The echo of the fault, and there is a large choice of ideal test waveforms.

 

Different impulse high voltages, different cable lengths, different cable fault distances, and the period and duration of large cosine oscillations are very different. The waveform collected by the simple secondary pulse method is often disturbed by the large cosine oscillation due to insufficient transmission delay time, and the waveform is chaotic and difficult to analyze. It can only be ensured by adjusting the delayed launch time of the test pulse or using a medium-voltage arc-extending device, which increases the difficulty of operation and the weight and cost of the equipment. The multiple pulse method just overcomes these difficulties and greatly simplifies the testing procedures. Eight sets of test waveforms are obtained from the high-voltage flashover process of one impact, and there are always several sets of waveforms that are convenient for fault distance interpretation. This is also the advantage of the multiple pulse method compared with the second pulse method.

 

Operation system show

20220811161625a414f4693cd346c2a4dd4daa89e1ee8b

 

Technical parameters

Sampling frequency

400MHz

Minimum resolution

0.5m (100m/us)

Low voltage pulse width

0.2uS

Test blind zone

≤20m

Ranging range

≤60km

Measurement error

≤±(0.5%×L+1m), L is the cable length

There are three test cable lengths

<1km (short distance); <3km (medium distance); >3km (long distance), (low-voltage pulse test amplitude: 400Vpp)

Pulse coupler withstand voltage

DC 35kV

Working conditions

temperature -25℃~+65℃, relative humidity 85%, atmospheric pressure 750±30mmHg

Volume and weight

Cable fault tester 430×380×220mm-10kg;

Pulse coupler 430×380×220mm-10kg

 

XHGG502 ARC cable fault pre locator automatically displays the reflected signal from the pulse coupler and displays the full-length waveform of the cable open circuit at the same time. It will automatically calculate and display the fault distance, and can store the waveform of the field test, which is easy to recall and observe at any time.

 

This cable fault tester also has a USB communication interface for connecting to a printer. Built-in lithium battery, suitable for testing cable faults in a no-power environment.

 

Panel introduction

20220811161904374526079e584578a0f2d9dcace19c94

1 .Display: 12.1-inch industrial-grade touch screen;

2 .Communication: low-voltage pulse method pulse signal output interface, high-voltage flashover method sampler receiving signal input interface;

3. Grounding: safety grounding terminal;

4 . Power indicator: Indicates the internal battery power, displayed in 4 grids;

5. USB-1: External wireless network card and USB communication device;

6 .USB-2: External wireless network card and USB communication device;

7 .Power switch: "I" position, use AC 220V power supply to supply power to the system;

The “II” gear uses the internal battery to power the system; when the “power socket” is connected to the AC 220V power supply, it also charges the battery at the same time;

"O" gear, turn off the system power;

8 .Power socket: working power supply of the instrument, AC 220V connection port;

9 .Fuse: the place where the fuse of the AC 220V power supply system is installed;

10 .Self-check: transmit signals under multiple pulses;

11. On/Off: Turn on and off the working power of the industrial computer;

12 .Amplitude: Adjust the amplitude knob when collecting waveforms to change the amplitude of the collected waveforms;

13. Indicator light: the indicator light reflecting the inspection method;

14. Displacement: Adjust the displacement knob when acquiring waveforms to change the baseline height of the acquired waveforms;

 

Customer success testing case

20220811162051abc39c4487734ccd4d26ec6c

 

20220811162149ffef6de122534efb97f21d32e0e1d533

 

20220811162233653e6e3b11b64fccaaa2f03159b6a27d

 

Packing list

Remarks

◆This cable pipe locator has passed the international standard certification CE ISO

◆Lead time is 5-8 days. The specific situation can be negotiated when you place an order.

◆The transport package is a special wooden box with bubble cotton inside. very safe.

202208111634052820286a1b874abb969cd932bd7a0aa7

 

◆We usually deliver equipments by FEDEX, DHL, , ARAMEX, etc. It can be negotiated according to different countries.

20220811163351f6ac0f9b1126493e9faf0f14

 

◆XZH Team is a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.

 

202208111634389f28bc3b788947d8924be9818a4e6ac4

 

XZH TEST   Welcome your inquiry~

 

FAQ

Q: Would you accept OEM order?

A: Yes, we accept, welcome you contact us for more discussion.

Q: What’s your terms of payment?

A: Payment terms can be negotiated, in general, Payment≤USD2000, 99% paid in advance.

Amount over USD2000, can be negotiated.

Q: Why should you buy the product  from us?

A: Professional R&D and technical support.

Provide overall laboratory solutions to your project.

Strict quality control and one year of warranty.

Short lead time and fast delivery.