High Voltage Surge Generator

Model
Nature of the Manufacturer
Manufacturer
Product Category
Power Cable Testing Equipment
Place of Origin
City, Province
Overview
Impulse voltage: 0~32kV、0~16kV、0~8kV(Adjustable)High voltage partial pressure: 1.5 levelBuilt-in capacitor: 4μF/32kV、16μF/16kV、64μF/8kV Discharge power: 0-2048J at each voltage level Impact time: about 5 seconds for automatic impact, arbitrary control time for manual impact Surge power: 2KVAWorking power supply: AC 220V±10% / 50Hz±2Hz(60Hz optional)Ambient temperature: -20~+50℃
Product Details

The XHHV535-4TS high voltage surge generator can be used impulse discharge and withstand voltage test in low and high voltage cable fault test. High-precision test cable fault sampling waveform module and small transformer are installed inside, it can not be damaged by impact, it got function of cycle(automatic timing impact), single(manual impact), and withstand voltage test.


The device has built-in high-voltage DC power supply, energy storage capacitor, discharge ball device, automatic discharge device, and voltage level switching device. It is a trolley-type high-end experimental instrument. The equipment completely solves the problems of ease of use, portability, safety and reliability of traditional experimental devices.


When the XHHV535-4TS trolley-type high-voltage surge generator is in use, after selecting the function switch, press the start button to perform high-voltage boosting work. After use, press the stop button, and the internal system will automatically release the remaining high voltage on the accumulator.




Working principle

                   _20220816132555




Panel introduction

_20220621165631



1. Ammeter: Indication of the current on the low-voltage side.


2. Voltmeter: high-voltage output voltage indicating kV meter, divided into 8kV, 16kV, 32kV combined with voltage level switch reading.


3. Power light (Power): After turning on the power switch, the indicator light is on, indicating that the AC220V is normal.


4. High voltage lamp (HV): On means there is high voltage output, and off means there is no high voltage output.


5. Zero position light (Zero): Indicates that the pressure regulating knob is in the zero position state, and the start button is only valid when it is on.


6. Signal: Connect the machine and the cable fault tester with double Q lines to collect waveforms for flashover, which is only valid for high-voltage flashover.


7. Power switch (ON/OFF): AC 220V 50Hz power input socket, safety seat and device

The main switch of the backup power supply is an 8A fuse when it leaves the factory.


8. Single key (Single): When the mode selection key is in the Single function, this key is valid.


9. Mode select: There are three modes: withstand voltage (DC), single (Single), and cycle (Cycle). WV is the withstand voltage function. When this function is selected, the cable is subjected to withstand voltage test at this time; Single is a manual function. When this function is selected, the high voltage will be boosted after starting, and the impulse discharge can be manually triggered by pressing the Single button; Cycle is an automatic function. When this function is selected, the high voltage is activated to boost the voltage, and the instrument will automatically trigger the shock discharge for about 5 seconds.


10. Start button (Start): in the zero position, press the start button, at this time the high voltage starts and the high voltage light is on. In the non-zero state, the start high pressure light does not light up.


11. Stop button (Stop): When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, and at this time, the remaining high-voltage in the test stop will be automatically discharged.


12. Voltage control: When this knob is in the zero position, the zero position light is on, and the high voltage can be started. After the high pressure is started, the pressure can be boosted through the pressure regulating knob.


13. Voltage rotation mode (Voltage select): This button has three voltage level modes, 8kV, 16kV, 32kV, please rotate to the appropriate position before starting. Lift, rotate, press.






_20220621165618_

XHHV535-4T Back_





Technical parameters

Impulse high voltage

0~32kV, 0~16kV, 0~8kV three gear adjustment

High voltage partial pressure

1.5 level

Built-in capacitor

4μF/32kV、16μF/16kV、64μF/8kV Adjustable three-speed adjustment

Discharge power

both are 2048J

Impact power

2KVA

Output voltage polarity

negative polarity

Impact time

about 5 seconds for automatic impact, arbitrary control time for manual impact

Over temperature protection

85℃

Volume(mm)

534L×444W×805H

Weight

not more than 130kg

Power supply

AC220V±10%, 50Hz±2Hz(60Hz can be customized)

Ambient temperature

-20~+50℃


_20220907153124




The high voltage surge generator also has the function of zero-start protection, which can make the operation of the device more safe and reliable. It has super short-circuit protection function, which can make the high-voltage output work directly to the ground. With 8/16/32KV three voltage range and capacitance capacity switching function, users can choose different equipment voltage adaption gears according to different cable voltage needs, making the test process easier.




Onsite test


_20220816133541__20210928085244_




Packing List

Instrument composition list and diagram

Name

Qty.

Picture

Name

Qty.

Picture

Host

1

image

power cable

1

image

HV output line

1

image

ground wire

3

image

Fuse 8A

3

image

discharge rod

1

image



Remarks


◆The standard packaging is a wooden box for export to protect the safety of equipment transportation.

◆The general delivery time of the equipment is 7-10 days. The specific negotiation at the time of ordering shall prevail.

◆Usually shipped by international express, such as FEDEX, DHL, , ARAMEX, etc. It can be negotiated according to different countries.



_20220806155356__

_20220806155402__

◆XZH Team is a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.



FAQ

Q: Are you trading company or manufacturer?

A: We are manufacturer.

Q: What’s your terms of payment?

A: Payment≤USD2000, 99% paid in advance. Amount over USD2000, can be negotiated.

Q: Why should you buy the High voltage surge generator from us?

A: Professional R&D and technical support, accept OEM, ODM orders;

Provide overall laboratory solutions to your project.

Strict quality control and one year of warranty.

Short lead time and fast delivery.