Impulse voltage: 0-15kV (optional)High voltage partial pressure: 1.5 classBuilt-in capacitor: 8μFDischarge power: 0-900 J Output voltage polarity: negative polarityImpact power: 400WOver temperature protection: 85℃Working power supply: AC 220V±10% / 50Hz±2Hz(60Hz can be customized)Ambient temperature: -20~+50℃
Product Details
Description
The XHHV515-8L low voltage surge generator is a tie-rod portable integrated device. It is mainly used for shock discharge during low-voltage cable fault testing. The pulse generator adopts humanized design operation mode, high-precision dedicated high-voltage electronic components and high-frequency high-voltage technology, which is easy to operate, light in weight and easy to carry.
It integrates the energy storage capacitor, DC high voltage source, and discharge ball gap. The operation of this equipment is safe and reliable, with automatic protection functions of over-current, overvoltage and overheating, it can truly achieve the effect of not being damaged by impact, and it can also work normally with high voltage to ground.
The XHHV515-8L Low voltage surge generator is equipped with a time relay, and the discharge time interval can be arbitrarily set within 0-100 seconds. When working, the high-voltage pulse output is uniform and controllable, high-voltage side voltage measurement, make the result real-time and accurate. Unique high-voltage measurement design, in the stop state, the voltmeter can indicate the capacitor voltage in real time. The user can observe the residual voltage while discharging, until the voltage value returns to zero, and finally make the discharge more thorough.
Panel introduction
1. Safety ground: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified or electric shock to personnel.
2. High-voltage ground: Also known as high-voltage tail, it must be grounded reliably to prevent high-voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.
3. Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled under the high-voltage flashover state of the cable fault locator. (Without high-voltage flashover sampling, reliable grounding is still required).
4. Discharge button: in the high voltage stop state, press this button to manually discharge the ball.
5. High voltage start button: When the start button light is on, it means that the voltage output is in the zero position. When it is on, the start button is valid. If the start button light is not on after turning on the power switch, adjust the voltage adjustment knob counterclockwise until the light is on. When the button light is on, press this button to start the device and generate high voltage output.
6. High-voltage stop button: When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, the high-voltage light goes out, and the internal discharge ball stops working. When the stop key is on, it means there is high voltage output, and when it is off, it means there is no high voltage output.
7. Voltage adjustment: After starting the device, you must first turn the knob counterclockwise to the end, and then adjust clockwise to increase the output high voltage from small to large, and adjust counterclockwise to decrease the output high voltage from large to small.
8. Power switch: "I gear" turns on the AC 220V power supply switch of the mains, and "0 gear" turns off the system power.
9. Fuse socket: 220VAC power supply system fuse installation place;
10. Power socket: working power supply of the instrument, 220VAC connection port;
11. Time setting: Set the discharge time interval.
12. Voltmeter: high voltage output voltage indicating kV meter.
13. High voltage output: dedicated high voltage pulse output terminal.
Technical parameters
Impact high voltage
0~15Kv
High voltage partial pressure
1.5 level
Built-in capacitor
8μF
Discharge power
0-900J
Output voltage polarity
negative polarity
Impact power
400W
Allowable impulse voltage
0~15kV
Allowable impact energy
0-900J
Over temperature protection
85℃
Volume(mm)
520L×300W×390H
Weight
not more than 40kg
Power supply
AC220V±15%, 50Hz±2Hz(60Hz can be customized)
Ambient temperature
-20~+50℃
Notes on Relays
Example
Adjust the time setting of the low voltage surge generator, the left half time is the ball suction time setting, the right half is the disconnection time setting, usually we set the time to 0 1 0.1S 0 6 S , which means that the two balls collide and discharge once in 6S time, and disconnect in 0.1S time ,As shown below:
Packing List
Instrument composition list and diagram
Name
Qty.
Picture
Name
Qty.
Picture
Host
1
power cable
1
High voltage output line
1
ground wire
1
Fuse
1
discharge rod
1
Package-By standard wooden case filled with foam.
Onsite test-It is portable, good performance, widly used and praised by customer.
Other design of low voltage surge generators XHHV515-8
Portable with output voltage 0-15KV adjustable, automantic discharge, discharge energy 900J
WELCOME YOU CONTACT US FOR MORE INFORMATION
Remarks
◆This pointing device has passed the international standard certification CE ISO
◆The general delivery time of the equipment is 5-8 days. The specific negotiation at the time of ordering shall prevail.
◆The standard packaging is a wooden box for export to protect the safety of equipment transportation.
◆Usually shipped by international express, such as FEDEX, DHL, , ARAMEX, etc. It can be negotiated according to different countries.
◆XZH Team is a young team. Our development philosophy is humanized management, intelligent cloud-based products, and internationalized operations. Our development mission is to make electrical equipment free from undetectable failures.
FAQ
Q: Are you trading company or manufacturer?
A: We are manufacturer.
Q: What’s your terms of payment?
A: Payment≤USD2000, 99% paid in advance. Amount over USD2000, can be negotiated.
Q: Why should you buy the low voltage pulse generator from us?
A: Professional R&D and technical support, accept OEM, ODM orders;
Provide overall laboratory solutions to your project.