Impulse voltage: 0~35kV (default 0~28kV)High voltage partial pressure: 1.5 classBuilt-in capacitor: 4μFDischarge power: 0~2450 J (default 0~1568 J)Output voltage polarity: negative polarityImpact power: 400WOver temperature protection: 85℃Working power supply: AC 220V±10% / 50Hz±2HzAmbient temperature: -20~+50℃
Product Details
Description
The XHHV535-4Z high voltage pulse generator is a system used to generate DC high-voltage pulse signals and generate electrical test signals with required parameters. It is often used as an impulse high-voltage power supply for fault detection of power cables with voltage levels of 35kV and below.
It integrates DC high voltage source, energy storage capacitor and discharge ball gap. Using high-precision, high-stability special high-voltage electronic components and high-frequency high-voltage technology, the structure is simple, the weight is ultra-light, the operation is easy, safe and reliable. Thishigh voltage surge generator really achieves the effect of not being damaged by impact, and it can also work normally with high voltage short circuit to ground.
The XHHV535-4Z High voltage pulse generator consists of a charging circuit and a discharging circuit. It samples the voltage of the high-voltage cable and sends it to the voltage regulator control circuit. It is usually used in high-voltage flashover fault testing and acoustic-magnetic synchronization fault point determination.
Cable fault test field wiring diagram
Technical parameters
Impact high voltage
0~35Kv
High voltage partial pressure
1.5 level
Built-in capacitor
4μF
Discharge power
2450J
Impact power
400W
Over temperature protection
85℃
Volume(mm)
420L×325W×480H
Weight
not more than 40kg
Power supply
AC220V±15%, 50Hz±2Hz(60Hz can be customized)
Ambient temperature
-20~+50℃
Main performance characteristics
With the functions of over-current, over-voltage, overheating protection function;
High voltage pulse output is even and controllable.
With super short circuit protection function , the high voltage pulse generator enable the HV output to work when directly shorted to grounded
With current and voltage 1.5 pointer display and the surge discharge process is intuitive and clear.
High voltage side measurement is real-time and accurate.
With zero start protection, and potentiometer return to zero output function, safe and reliable;
This unique design of high voltage measurement, at stop state, the voltage meter can real-time indicated the capacitor voltage.
Discharge time can be any set in the appropriate interval.
Panel introduction
1. High voltage output: dedicated high voltage pulse output terminal, output DC high voltage signal.
2. Safety ground: The ground of the instrument shell must be reliably connected to the ground in order to prevent the instrument shell from being electrified or electric shock to personnel.
3. Time setting: Set the discharge time interval.
4. Voltmeter: high voltage output voltage indicating kV meter.
5. Power socket: the working power of the instrument, AC 220V/50Hz.
6. Fuse socket: the place where the fuse of the 220VAC power supply system is installed.
7. Power switch: "grade I" uses AC220V power supply to supply power to the system, and "grade 0" shuts down.
8. Discharge button: In the high-voltage stop state, press this button to manually discharge the internal power.
9. Start button: When the start button light is on, it means that the voltage output is in the zero position. When the start button is on, the start button is valid. If the start button light is not on after turning on the power switch, adjust the voltage adjustment knob counterclockwise until the light is on. When the light is on, press this key to start the high voltage and generate high voltage output.
10. Stop button: When the test is completed or an abnormality occurs, press this button to cut off the high-voltage output, the high-voltage light goes out, and the internal discharge ball stops working. When the stop key is on, it means there is high voltage output, and when it is off, it means there is no high voltage output.
11. Voltage adjustment: After starting the device, you must first turn the knob counterclockwise to the zero position, then adjust clockwise to increase the output high voltage from small to large, and adjust counterclockwise to decrease the output high voltage from large to small.
12. Ammeter: Indication of low voltage measurement current.
13. Sampling ground: The negative terminal of the pulse energy storage capacitor has a high voltage and must be grounded reliably. It is used for sampling when the waveform is sampled under the high-voltage flashover state of the cable fault tester. (Without high-voltage flashover sampling, reliable grounding is still required).
14. High voltage ground: Also known as high voltage tail, it must be grounded reliably to prevent high voltage leakage and discharge. Poor contact may cause failure to boost the voltage, high voltage breakdown of the internal components of the instrument, and safety accidents caused by leakage or discharge inside the instrument.
Testing and package
Packing List
Instrument composition list and diagram
Name
Qty.
Picture
Name
Qty.
Picture
Host
1
power cable
1
HV output line
1
ground wire
1
Fuse
2-3
discharge rod
1
Onsite testing
Other design of high voltage pulse generator
XHHV535-2L(35KV/2μF)
XHHV535-4(35KV/4μF)
WELCOME YOU CONTACT US FOR MORE INFORMATION
Let the power equipment have no unpredictable failures.
XZH TEST welcomes your inquiry.
FAQ
Q: Are you trading company or manufacturer?
A: We are manufacturer.
Q: What’s your terms of payment?
A: Payment≤USD2000, 99% paid in advance. Amount over USD2000, can be negotiated.
Q: Why should you buy the high voltage pulse generator from us?
A:Professional R&D and technical support, accept OEM, ODM orders;
Provide overall laboratory solutions to your project.