Welcome Customer !

Membership

XZH TEST
Free Member ·1YRS
XiAn,ShanXi
Manufacturer

Main Products: Transformer Testing Machine|Other Testing Machines

Xwboo>Products

XZH TESTFree·1YRS

  • E-mail

    happyxzh@xzhjdkj.com

  • Phone

    86-029-86093121

  • Address

    Building B8-01, Phase I, Ronghao Industrial City, No. 2098, Weiyang 9th Road, Gaoling District, Xi'an City, Shaanxi Province, China

Contact Now

Cable Fault Test Van

Model
Nature of the Manufacturer
Manufacturer
Product Category
Power Cable Testing Equipment
Place of Origin
City, Province
Overview
Cable Fault Test Van can perform routine cable tests, fault tests, and positioning. Due to the use of the most advanced measurement methods and centralized control of industrial computers, the system is easy to operate and powerful. XHDLJC system can also be customized according to different...
Product Details

Cable Fault Test Van can perform routine cable tests, fault tests, and positioning. Due to the use of the most advanced measurement methods and centralized control of industrial computers, the system is easy to operate and powerful. XHDLJC system can also be customized according to different applications


1. System design

◇Overall design:

Model: 17-seater Iveco

Layout: balanced counterweight, overall coordination and aesthetics, humanized work platform.

◇Partial design:

1)Generator: On the left side of the back door of the test vehicle, a dedicated hydraulic door and rail groove for the generator are installed, and the generator is pulled out and opened to the outside world when it is working. The rail groove is equipped with a latch to prevent the generator from sliding. It can also be directly installed in the car, which is more convenient to use.

2)Power supply system configuration: over-current, over-voltage protector. Concealed installation location, strengthen power supply and ensure safety.

3)Placement of auxiliary parts: design and process the bracket with lock, and the installation position meets the requirements of practical convenience.

4)Vehicle lighting: LED lamps are added to the top of the car body to ensure sufficient light in the car.

5)Utilization of main equipment space: The front side door is designed and processed with drawer-type toolboxes and equipment cabinets to fill the space, and the main equipment is placed on the left side of the side door to make the layout of the car more beautiful and reserve enough space for the operators.

6)The overall operation control of the system is completed by a 15-inch industrial-grade computer, which acts as a central control unit for the operation and control of all equipment and test items.

7)The system has all the functions of an ordinary PC and is equipped with a laser printer to print field test data and test reports at any time.

8)The system is equipped with standard power switch, high voltage output switch and emergency stop button.

9)The high-voltage equipment of the system is completely isolated from the operation room. Equipped with central air-conditioning to make the operator more comfortable to work.


2. Basic function

★ Use the principle of traveling wave reflection to conduct rough measurement of the main insulation faults of all types of cables

★Use the Acousto-Magnetic Synchronous Method to perform precise measurement of all types of cable main insulation faults

★Use the principle of bridge balance to conduct a rough measurement of the sheath fault

★ Use the step voltage method and the clamp current method to accurately locate the sheath fault

★ Conduct AC withstand voltage test (0.1Hz) on power cables of 35kV and below

★Use the audio method to directly locate the low-voltage cable fault

★Use the principle of electromagnetic induction to accurately find the unknown cable path and depth

★Use the phase method to identify multiple cables

★Use the remote-control method to confirm the final damage to the cable.


3. Cable Fault Test Van include:

★ Intelligent 400V-220kV cable fault location system

★ Intelligent remote control cable identification and stabbing system

★ Rough detection and precise positioning system for faults of high-voltage cable outer sheath

★ Low-voltage cable fault location system for low-voltage cables, street lamp cables, lighting cables

★ Ultra-low frequency cable test and insulation diagnosis system

★ Necessary tools and equipment for cable inspection and test site


4. System composition

1) Imported generator, special workbench, testing software and cable management system

Imported generator 6KW gasoline generator


System composition


Gasoline engine type

Horizontal bar four stroke 0HV

Displacement

438CC

Frequency

50HZ

Ignition system

Transistor magnet ignition

Rated output power

6.3KW

Fuel tank volume

25L

Maximum output power

6.6KW

Fuel consumption

G/(kw.h)≤360

Rated voltage

230/400V

Operating hours

7H

Battery capacitor

9Ah

Engine oil capacity

1.1L

gasoline engine

EU440D

Dimensions

L×W×H 677*532*551mm

Phase

Single phase

N.W.

85kg


CPU type: Intel/Intel Core i7 quad core 3.0GHz and above

Memory type: DDR4 8GB Memory frequency: 2133MHz

Hard disk type: 120GB electronic hard disk


2) XHGG502 Cable fault flash tester (invention patent: ZL2015 1 0712758.2)

XHGG502 Cable fault flash tester


XHGG502 multi-pulse cable fault tester is used to detect high-resistance leakage faults, flashover faults, low-resistance grounding and open circuit faults of various power cables.


Main performance indicators:

1) 1. It can measure the high and low resistance faults of all cables below 35kV.

2) The pulse generator withstands the impact high voltage: not less than 45kV

3) Data sampling rate: 200MHz

4) Test distance:<>

5) No test blind area

6) Reading resolution: 0.1m

7) System test accuracy is less than 20cm

8) There are three test cable lengths:<1km (short="" distance);=""><3km middle="">3km (long distance) (test low-voltage pulse amplitude: about 400VP-P)

9) Multiple pulse transmission and fault reflection signals are automatically displayed, and the full-length waveform of the cable open circuit is displayed at the same time. It makes the representation of the fault characteristic waveform extremely simple. There is only one kind of waveform for all high-impedance faults, that is, the short-circuit fault waveform similar to the low-voltage pulse method. Automatic display of fault distance. There are no test blind spots.

10) It has a massive test waveform storage function: the waveforms tested on site can be conveniently stored in the instrument according to the specified order, and can be recalled and observed at any time.

11) The measured waveform of the fault point and the full-length open circuit waveform of the good phase can be displayed on the screen at the same time for comparison on the same screen and superimposed comparison. It makes the judgment of fault distance more accurate.

12) Three test methods: multiple pulse method (ARC), low voltage pulse method and high voltage flashover method

13)The instrument adopts the latest technology of embedded industrial computer, Windows-xp system.


3) XHDD503D Synchronous receiving pointing instrument

XHDD503D Synchronous receiving pointing instrument


The cable fault locator uses the acoustic method to determine the power cable fault point. With the help of an impulse discharge generator, an electronic flashover is generated. The acousto-magnetic signal of the electronic flashover wave is picked up and amplified by the corresponding probe, and judged by hearing and vision. To determine the precise location of the fault point, that is, to complete the precise positioning task within the rough measurement range of the cable fault point.


Main performance

★It can synchronously receive the sound wave and electromagnetic wave generated when the fault point is discharged, which is used to determine the location of the cable fault point.

★The magnification is 500,000 times.

★Operating Voltage:±9V±20%

★Quiescent Current:<10mA

★Receiving signal: vibration and magnetic field signal when the fault point is discharged

★Output impedance:350Ω

★positioning accuracy:0.2m


4) XHGX507 Cable fault comprehensive tester

4)XHGX507 Cable fault comprehensive tester


XHGX507 cable fault comprehensive tester can be used to find the cable (live or uncharged) path and identification, but also can be used to find the direct buried cable fault.

Instrument features:

★All-digital locator, clear display and reliable positioning

★Portable and lightweight, easy to use, quick to find

★Built-in rechargeable battery, no utility power is needed for testing

★With cable buried depth display, current display

★Large-screen LCD graphic display, no earphones required during testing

★Built-in ohmmeter can measure cable loop resistance

★With two functions of cable location and fault finding

★Insulation faults to ground up to 2MΩ can be found

★With backlight function to adapt to night operation

Performance

①.Receiver

★Working frequency: low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz), 50Hz

★Antenna mode: valley method (zero value mode), crest method (peak mode), step voltage method and clamp current method (A-frame)

★Sound indication: FM tone that changes with signal strength

★Current indication: display the effective current value of the cable under test (unit: mA)

★Working temperature: -10℃+55℃

★Battery model: 6 AA alkaline batteries

★Power indicator: graphic display

★Battery life: continuous work> 8 hours: intermittent work> 16 hours

★Size: 70×20×11cm

★Weight: 3kg (with battery)

★Signal strength indication: ladder diagram, digital range 0-999

★Gain control: manual adjustment, dynamic range of 100dB

★Detection depth: the maximum detection depth is not less than 5 meters

★Maximum detection distance: The cable with good insulation can be up to 15km in the direct connection method

★Depth measurement: press the depth key to display three digits, the maximum depth can be measured up to 10 meters

★Accuracy: Low frequency: ±(1-5)%≤2.5m Radio frequency: ±(5-12)%≤2.5m

★Depending on the site environment, the shape of the non-concentric lines, the number of adjacent pipelines, and the return current of the soil


②.Transmitter

★Working frequency: low frequency (815Hz), intermediate frequency (8kHz), high frequency (33 kHz), radio frequency (83 kHz)

★Working mode: direct connection method, coupling method (caliper method), induction method

★Matching load: 5 ohms—3000 ohms

★Impedance display: five digits

★Overheating and overcurrent: automatic protection

★Power output: low gear, middle gear, high gear


5) XHHV532-4TS High-voltage integrated test device

5)XHHV532-4TS High-voltage integrated test device

This device integrates a high-end experimental instrument with a DC high-voltage source, an energy storage capacitor, a discharge ball device, an automatic discharge device, and a cable fault tester.It is mainly used for impulse discharge and withstand voltage test during low and high voltage cable fault test.


Main performance characteristics:

★ High-voltage pulse output is uniform and controllable;

★ With current and voltage double 1.5-level pointer meter display, it is intuitive and clear, and the impact discharge process is clear at a glance;

★ High-voltage side voltage measurement, real-time and accurate;

★ With zero start protection function, safe and reliable;

★ Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device;

★ The discharge time can be selected in two modes: timing and manual;

★ With DC withstand voltage function;

★ Install high-precision test cable fault sampling waveform module inside;

★ Humanized design trolley, easy to move.

Main Specifications:

★ Impact high voltage: CD 0~8/16/32kV

★ Built-in capacitor: correspond 64/16/4μF

★ Discharge power:2048J

★ High voltage divider: voltage accuracy level 1.5

★ Impact time: automatic impact for about 5 seconds, manual control time arbitrarily

★ Impact power:2kVA

★ Power supply: AC 220V±10% 50Hz±2Hz

★ Ambient temperature:-20~+50℃


6) XHHG521 Cable sheath failure tester

6)XHHG521 Cable sheath failure tester

The XHHG521 cable fault tester is designed based on the principle of MURRAY bridge. It can be used to locate the breakdown points of various wires and cables after laying and the defect points with no breakdown but low insulation resistance. Of course, it can also be used to locate the defect points of various cables in the cable factory.

Especially suitable for

★The high-resistance breakdown point of the cable after laying, especially the low-resistance linear high-resistance breakdown point, such as the linear high-resistance breakdown of the cable middle joint.

★Flashover type breakdown point, after breakdown, the constant current source can maintain the arc, there is a stable current through the bridge, and the bridge has sufficient sensitivity.

★Defects that have not been broken down, but have low resistance, such as insulation defects that have low cable resistance but do not break down under operating voltage.

Technical index

★No-load voltage ≥5000V

★Short circuit current ≥40mA

★Positioning proportional accuracy ±(0.2%·L±1) m


7) XHHD523 Sheath fault locator

7)XHHD523 Sheath fault locator

The output voltage of the high-voltage cable outer sheath fault detector is 10kV and below. It can quickly and accurately find hidden dangers such as grounding faults and large leakage currents in the outer sheath of 10kV-500kV single-core and three-core high-voltage and ultra-high-voltage cables. 5kV-10kV, 1 minute DC withstand voltage test for polyethylene and polyvinyl chloride cable outer sheath, is 10kV-500kV single-core and three-core high-voltage, ultra-high-voltage cable operating units, ultra-high-voltage cable engineering companies, various power transmission and transformation It is a special instrument necessary for the maintenance of cable equipment in engineering companies.

Main features

Ø★Voltage adjustable

Ø★Frequency adjustable

Ø★Overcurrent protection

Ø★One-key switch between fixed point and withstand voltage

Ø★ No blind zone in the test range

Ø★Receiver sensitivity is adjustable.

Ø★Signal frequency adjustment

Ø★Zero protection

Main Specifications

★ Input voltage: 220V (1±10%), 50Hz (1±5%)

★Output voltage: 0 ~ 10kV (square wave) adjustable

★Output current: max 200mA

★Output capacity: 2kVA

★Frequency adjustment: Min: 0.4Hz, Max: 1Hz (range adjustable)


8) XHZS506S cable stabbed device(cable spiker)

8)XHZS506S cable stabbed device(cable spiker)

main parameters

It is mainly composed of a controller, a remote control, and a piercing gun body.

★ The 506S double gun produces two short-circuit points on the cable at the same time.

★ It is controlled by wireless remote control, the remote control distance is more than 10 meters, and it can be remotely controlled by partitions. The safety performance and reliability are higher than infrared. The control line is 5 meters long.

★ AC and DC dual purpose, built-in 10Ah lithium battery, long charging time, more than 10 hours of continuous work.

★ Caliber width of clamp: 30-160mm.

★ Small size and light weight, very suitable for field use

★ Power supply:AC 220V±10% 50Hz/DC 12V 3A

★ Controller:270×230×120mm 2.5kg

★ Whole set:470×380×210mm 15.5kg(Double gun 506S)


9) XHDP-80 VLF high voltage generator (0.1Hz)

XHDP-80 VLF high voltage generator (0.1Hz)


Features:

★The ultra-low frequency with a rated voltage less than or equal to 50kV adopts a single-connected structure (one booster); the ultra-low frequency greater than 50kV adopts a series structure (two boosters connected in series), which greatly reduces the overall weight and enhances the load capacity , and the two boosters can be used independently for ultra-low frequency at low voltage levels.

★Current, voltage, and waveform data are directly sampled from the high-voltage side, so the data is accurate.

★With overvoltage protection function, when the output exceeds the set limit voltage value, the instrument will stop for protection, and the action time is less than 20ms.

★With overcurrent protection function: designed as high and low voltage dual protection, the high voltage side can be accurately shut down according to the set value; when the current of the low voltage side exceeds the rated current, it will be shut down, and the action time is less than 20ms.

★The high-voltage output protection resistor is designed in the boost body, so there is no need to connect another protection resistor outside.

★Due to the high and low voltage closed-loop negative feedback control circuit, the output has no capacity boost effect.

Technical parameter

★Output rated voltage: 80kV (peak value)

★ Output frequency: 0.1Hz, 0.05Hz, 0.02Hz

★Load capacity: 0.1Hz maximum 1.1µF 0.05Hz 2.2µF max 0.02Hz 5.5µF max

★ Measurement accuracy: 3%

★Voltage positive and negative peak error: ≤3%

★ Voltage waveform distortion: ≤5%

★Conditions of use: Temperature: -10℃∽+40℃; Humidity: ≤85%RH

★ Power supply: frequency 50Hz, voltage 220V±5%.


10) Auxiliary test tools: test leads, megohmmeter, measuring instrument, phase measuring instrument and test lead

★High voltage line: 50m 80kV

★Grounding wire: 50m 10mm2

★Power cord: 50m single phase


Megohmmeter

★Output voltage: DC500V/1000V/2500V/5000V±10%

★Short circuit current: >5mA

★Range 0.2MΩ-100GΩ

★Ambient temperature: -10℃-+50℃

★Environmental humidity: ≤75%RH

★Measurement accuracy:

0.3MΩ-5000MΩ (500V) 5%

1000KΩ-20000MΩ (1000V) 5%

3MΩ-50000MΩ (2500V) 5%

11 MΩ-100000MΩ (5000V) 5%

★Voltage ripple: the test voltage ripple content is not more than 3%


Measuring instrument

★Mainly used for accurate measurement of cable fault points.

★Maximum measuring range: 99999.9m, 99999.9ft

★Accuracy: ±0.3%

★Minimum display: 0.1m

★Power supply: 3V (2×AAA LR03)

VSuitable temperature: -10℃~45℃


Phasor

The power cable phase detector uses the phase principle to measure the phase sequence of the power cable. The cable is sampled by the phase detector and tested by the host. The test result is displayed by a three-digit digital tube. Overcome the difficult problem of the line length test.

Technical index

★Power supply: 4 AAA batteries

★Working time: about 20 hours

★LED display: display the phase sequence of the cable (A, B, C)

★Working environment: temperature: -40℃~+50℃

Humidity:<>

★Volume: 200×60×30

★Weight: 600g

Electrician tools A set of commonly used electrician tools


5. System list

Item

Name

Model

Qty.

1

Imported generator

6 kW gasoline generator

1 Set

Dedicated workbench, test software and cable management system

CPU type: Intel/Intel Core i7 quad core 3.0GHz and above Memory type: DDR4 8GB Memory rate: 2133MHz; Hard disk type: 120GB electronic hard disk

1 Set


2

Cable fault pre locator

XHGG502

1 Set

3

Synchronous receiving pointing instrument

XHDD503D

1 Set

4

Cable fault comprehensive tester

XHGX507

1 Set

5

High-voltage integrated test device

XHHV532-4TS

1 Set

6

Cable sheath failure tester

XHHG521

1 Set

7

Sheath fault locator

XHHD523

1 Set

8

Cable spiker

XHZS506S

1 Set

9

VLF high voltage generator (0.1Hz)

XHDP-80

1 Set

10

Auxiliary test tools (test lead, megohmmeter, measuring instrument, phase measuring instrument and test lead)


1 Set


Historical case

Historical case

Historical case 1

Historical case 2

Historical case 3


We can customize the whole cable test van according to your requirements.

We can also customize the complete set of devices in the van.


Welcome you contact us for further negociation.