HT-LA600 Flue Oxygen Analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
HT-LA600 Flue Oxygen Analyzer
Product Details

    Measurement Principle: Zirconia

    Display Mode: 4-digit high-light LED display

    Measurement Range:0~10.00%/25.00% O2

    Expanded Range: 0~10.00%/25.00%/40.00% O2 (oxygen-enriched combustion)

    Measurement Accuracy: ≤±1.5%FS

    Resolution: 0.01%

    Repeatability: ≤±1.0%FS

    Response Time: T90≤30S

    Output Port: 4-20mA (Non-isolated output, load resistance<1KΩ)

    0-5V.DC (Non-isolated output, load resistance>10KΩ)

    1 way of programmable alarm output (Dry contact type, maximum load 220V/2A)

    Communication Mode: RS485

    Power Supply: AC220V±10% 50/60Hz

    Calibration Method: Online calibration

    Instrument Operation Temperature: -10℃~+50℃

    Probe Operation Temperature: Normal type 0~200℃, high-temperature type 0~400℃, special type 0~650℃

    Holt-Cutting Size: Φ50mm~Φ90mm

    Probe Length: Standard length 1m, other length is customizable (≤1.8m)

    Sensor Service Life: >5 years (under normal conditions of use)

    Installation Method: Instrument: Wall mounting

    Probe: Plug-in (standard DN65 flanged mounting)

    a. OLED active illumination display makes the operation easy and convenient;

    b. The new type zirconia sensor has a high measurement accuracy, rapid response speed and small drift value, etc.;

    c. Use microprocessor as its core, which has excellent stability, high reliability and long calibration cycle, etc.;

    d. The instrument allows multi-point fractional liner calibration, meeting the need for an accurate measurement of oxygen content among the full range;

    e. Automatic temperature compensation function could eliminate the impact of environmental temperature changes on the measurement accuracy;

    f. Measurement range can be expanded to 0~40.00% (oxygen-enriched combustion), and its range can be switched automatically;

    g. User could set upper and lower limits of oxygen concentration of 4-20mA and 0-5V analog output to acquire a more accurate analog output result;

    h. Standard RS485 communication port allows a unidirectional or bidirectional communication with computer or other digital communication equipment.

    It is widely used in power, metallurgy, heating, building materials, electronics and other departments, to analyze the oxygen content of flue gas in various industrial boilers and kilns. It can also be used to monitor and analyze the oxygen concentration of combustion gas in large or small boilers, various industrial furnaces and combustion devices, in order to achieve low-oxygen reasonable combustion, reduce fuel consumption and burn loss, stabilize the process, improve product quality, reduce environmental pollution and other effects.

    Probe length

    Sample gas temperature

    Background gas composition