Welcome Customer !

Membership

Jiuyin Science and Technology Chengdu Co., Ltd.
Free Member ·1YRS
ChengDou,SiChuan
Manufacturer

Main Products: Oxygen Nitrogen Analyzer (Oxygen Nitrogen Hydrogen Analyzer)|Automobile Exhaust Gas Analyzer

Xwboo>Products

Jiuyin Science and Technology Chengdu Co., Ltd.Free·1YRS

  • E-mail

    sales@meas-elec.com,service@meas-elec.com

  • Phone

    028-85044052/028-85044053

  • Address

    4th floor, unit 1, building 4, District D, West Zhigu, 66, Wuxing 4th Road, Wuhou District, Chengdu City, Sichuan Province

Contact Now

HT-LZ103 Multi-Component Gas Analyzer

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
City, Province
Overview
HT-LZ103 Multi-Component Gas Analyzer
Product Details

    Display Mode: 640×480 dot matrix LCD touch screen

    Measurement Principle: O2 :ion current (limiting current)

    CO: fuel cell

    H2O: thin-film capacitor

    Measurement Range: O2: 10.00%~99.99% O2

    CO: 0~1000PPm CO

    H2O: -80.0℃~+20.0℃ (basic)

    -100℃~+20.0℃ (expanded)

    Measurement Accuracy: O2: ≤±1.0%FS

    CO: ≤±1.0%FS

    H2O: ≤±1.2%FS

    Repeatability: ≤±1.0%FS

    Response Time: O2: T90≤15S

    CO: T90≤30S

    H2O: T90≤50S

    Output Port: 3 ways of 4-20mA.DC (Non-isolated output, load resistance<1KΩ), corresponding to three kinds of measurement media;

    3 ways of programmable alarm output (Dry contact type, maximum load 220VAC/2A), corresponding to three kinds of measurement media;

    Communication Port: RS232 (default) or RS485

    Power Supply: AC170~264V 50/60Hz, power dissipation <25W

    Environment Temperature: -10℃~+50℃

    Storage Environment Humidity: <90%RH, non-condensing

    Operation Environment Humidity: <99%RH, non-condensing

    Sample Gas Temperature: 0℃~40℃

    Sampling Mode: Gas in

    Sample Gas Flow: O2/CO channel 400~600mL/min

    H2O channel 1.5~2L/min

    Flow Display: Electric flowmeter

    Sample Gas Pressure: Inlet pressure 0.1~0.5MPa, outlet pressure is atmospheric pressure

    Sensor Service Life: Oxygen sensor: >5 years (under normal conditions of use)

    CO sensor >3 years (under normal conditions of use)

    Dew point sensor >5 years (under normal conditions of use)

    Size: 176mm×350mm×360mm (H×W×D)

    Hole-Cutting Size: 178mm×307mm (H×W)

    Gas Circuit Port: NPT1/8 internal thread

    Installation Mode: Embedded mounting


    a. With big touch screen display, single screen would display 3 kinds of media concentration value, flow value and so on;

    b. The ion current sensor used to measure oxygen consumes no service life when power is off, and it has a high measurement accuracy and is easy to maintain, etc.;

    c. Original imported fuel cell sensor used to measure CO has rapid response speed, long calibration cycle and strong anti-interference capacity, etc.;

    d. Imported thin-film capacitor sensor is used to measure dew point, and it has high measurement accuracy, rapid response speed, excellent repeatability, etc.;

    e. Menu can be switched between Chinese and English and the operation is intuitive and convenient;

    f. Original imported mass flowmeter is built in and the flow is displayed straightly, and the flow meter has a long service life;

    g. Three kinds of measured media have temperature compensation function, and could reduce the impact of environmental temperature changes on the measurement accuracy;

    h. Historical data can be stored and user could read historical data and curve locally at any time;

    i. Altitude height measurement module can be expanded, preventing the impact of atmospheric pressure changes on the measurement accuracy;

    j. H2O and CO user could choose sensors with different ranges;

    k. Every kind of measured media is corresponding to one way of analog output and alarm output;

    l. Alarm buzzer is built in and is of redundancy of three kinds of media’s alarm points;

    m. With automatic protection function, the sensor needs no human intervention;

    n. No calibration gas is needed and the instrument is not affected by the oxygen content in the operation environment;

    o. It is of excellent selectivity for measured gas.



    It is used for online analysis and measurement in medical treatment, oxygen or gas generator, air separation, etc.



    Measured media range

    Measured media background gas composition